Abstract 4364915: Early Percutaneous Ventricular Assist Device Use Is Associated with Higher In-Hospital Mortality in Non-Ischemic Cardiogenic Shock: A National Inpatient Sample Analysis

Background: Cardiogenic shock (CS) is a life-threatening condition of inadequate organ perfusion due to cardiac failure. Although inotropes and vasopressors are standard treatments, they are linked with increased mortality and adverse effects. Mechanical circulatory support (MCS) devices such as intra-aortic balloon pump (IABP) and percutaneous ventricular assist devices (PVADs), including Impella, offer hemodynamic support with the potential for improved outcomes. While most evidence focuses on ischemic CS, the role and timing of PVAD in non-ischemic CS remain unclear. Objective: To evaluate the association between early (<24 hours) versus late (≥24 hours) PVADs use and in-hospital outcomes in patients with non-ischemic CS. Methods: We conducted a retrospective cohort study using the National Inpatient Sample from 2016–2022. We included adult patients with CS (ICD-10-CM R57.0) without concurrent acute myocardial infarction. Patients receiving PVADs (ICD-10-PCS) were categorized based on device implantation <24 or ≥24 hours from admission. The primary outcome was in-hospital mortality. Secondary outcomes included length of stay (LOS), hospitalization cost, and complications. Multivariable logistic and linear regression models were adjusted for demographics, comorbidities, and severity indicators. Results: Among 5,432 patients with non-ischemic CS treated with PVAD, 56.1% received early placement. In-hospital mortality was higher in the early group (39.6% vs 33.5%, p <0.001) and remained significant after adjustment. Early PVAD placement had shorter LOS (median 6 vs 17 days, p <0.001) and lower hospitalization cost (median $72,121 vs $123,166, p <0.001), likely reflecting early mortality. From 2016 to 2022, PVAD use increased (0.72% to 3.68%) while IABP use declined (10.2% to 5.5%). Conclusions: In patients with non-ischemic cardiogenic shock, early PVAD use was associated with increased mortality despite reduced resource utilization. These findings suggest early PVAD deployment may reflect greater disease acuity. Our findings suggest early PVAD placement may be harmful in some patients with non-ischemic CS and should not be used reflexively without clear clinical justification. Further studies are needed to clarify optimal timing and identify subgroups most likely to benefit from early support.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4364915
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4364915: Early Percutaneous Ventricular Assist Device Use Is Associated with Higher In-Hospital Mortality in Non-Ischemic Cardiogenic Shock: A National Inpatient Sample Analysis

Krystal Hunter, Dhara Rana, Naveed Sami, Lin Zheng
Circulation
Mechanical Circulatory Support Devices
article

Abstract 4364915: Early Percutaneous Ventricular Assist Device Use Is Associated with Higher In-Hospital Mortality in Non-Ischemic Cardiogenic Shock: A National Inpatient Sample Analysis

Krystal Hunter, Dhara Rana, Naveed Sami, Lin Zheng
article en

Abstract

Background: Cardiogenic shock (CS) is a life-threatening condition of inadequate organ perfusion due to cardiac failure. Although inotropes and vasopressors are standard treatments, they are linked with increased mortality and adverse effects. Mechanical circulatory support (MCS) devices such as intra-aortic balloon pump (IABP) and percutaneous ventricular assist devices (PVADs), including Impella, offer hemodynamic support with the potential for improved outcomes. While most evidence focuses on ischemic CS, the role and timing of PVAD in non-ischemic CS remain unclear. Objective: To evaluate the association between early (<24 hours) versus late (≥24 hours) PVADs use and in-hospital outcomes in patients with non-ischemic CS. Methods: We conducted a retrospective cohort study using the National Inpatient Sample from 2016–2022. We included adult patients with CS (ICD-10-CM R57.0) without concurrent acute myocardial infarction. Patients receiving PVADs (ICD-10-PCS) were categorized based on device implantation <24 or ≥24 hours from admission. The primary outcome was in-hospital mortality. Secondary outcomes included length of stay (LOS), hospitalization cost, and complications. Multivariable logistic and linear regression models were adjusted for demographics, comorbidities, and severity indicators. Results: Among 5,432 patients with non-ischemic CS treated with PVAD, 56.1% received early placement. In-hospital mortality was higher in the early group (39.6% vs 33.5%, p <0.001) and remained significant after adjustment. Early PVAD placement had shorter LOS (median 6 vs 17 days, p <0.001) and lower hospitalization cost (median $72,121 vs $123,166, p <0.001), likely reflecting early mortality. From 2016 to 2022, PVAD use increased (0.72% to 3.68%) while IABP use declined (10.2% to 5.5%). Conclusions: In patients with non-ischemic cardiogenic shock, early PVAD use was associated with increased mortality despite reduced resource utilization. These findings suggest early PVAD deployment may reflect greater disease acuity. Our findings suggest early PVAD placement may be harmful in some patients with non-ischemic CS and should not be used reflexively without clear clinical justification. Further studies are needed to clarify optimal timing and identify subgroups most likely to benefit from early support.

CirculationVol. 152(Suppl_3)
Inspira Medical Center Vineland (US), Cooper Medical School of Rowan University (US), Presbyterian Hospital (US)
Openalex Percentile: Top 69%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.