Abstract 4364999: Clinical Features And Hemodynamic Response of Microaxial Flow Pump Treatment in Cardiogenic Shock With or Without Myocardial Infarction

Background: Recent DanGer-Shock trial demonstrated potential mortality benefit of microaxial flow pumps (mAFP) in select patients with acute myocardial infarction cardiogenic shock (AMI-CS). However, the clinical profile, hemodynamic response, and outcomes of mAFP use in non-acute myocardial infarction cardiogenic shock (nonAMI-CS) remain less well understood. Methods: Patients treated for cardiogenic shock between 2016 to 2022 with mAFP support (Impella 2.5, CP, 5.0, or 5.5) were retrospectively identified. Those with pulmonary artery catheter derived hemodynamics before and after implantation were included. Baseline hemodynamics were defined as the last recordings prior to device placement; post-implant hemodynamics were defined as the median of recordings within 24 hours after placement. Treatment success was defined as survival to discharge without ECMO escalation. Wilcoxon rank-sum and Chi-square tests were used for comparisons. Results: Of 110 patients included, 65 (59%) had AMI-CS and 45 (41%) had nonAMI-CS. Compared to AMI-CS, nonAMI-CS group had higher prevalence of chronic kidney disease, heart failure, atrial fibrillation, lower baseline ejection fraction and larger left ventricular diameter. High-capacity mAFP (Impella 5.0/5.5) were more frequently used in nonAMI-CS (29% vs. 5%, p<0.01) whereas AMI-CS received predominantly Impella CP (95%). The culprit vessels among AMI-CS patients were predominantly left-sided (51% LAD, 26% LCx, 12% left main, 9% RCA, 2% OM1). Baseline hemodynamics were similar between groups. Post-implantation, AMI-CS patients showed greater reductions in CVP (-40% vs. -31%, p = 0.04) and mPAP (-27% vs. -17%, p=0.04), achieving lower absolute CVP (9 vs. 12 mmHg, p < 0.01) and mPAP (25 vs. 29 mmHg, p = 0.04). In contrast, nonAMI-CS patients had greater improvement in cardiac index (CI) (+29% vs. +5%, p<0.01) and achieved a higher post-implant CI (2.45 vs. 1.93 L/min/m 2 , p < 0.01). Treatment success rates were not significantly different (52% AMI-CS vs. 36% nonAMI-CS, p=0.08). Conclusion: NonAMI-CS patients received more high-capacity mAFP and showed greater improvement in CI, while AMI-CS patients experienced more pronounced decongestion without significant increase in CI and a trend toward higher treatment success. These findings highlight decongestion as a potential prognostic signal in this patient cohort.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4364999
Primary Topic
Mechanical Circulatory Support Devices
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4364999: Clinical Features And Hemodynamic Response of Microaxial Flow Pump Treatment in Cardiogenic Shock With or Without Myocardial Infarction

Matthew J. Pierce, Vladimir Shusterman, Shuojohn Li, Miguel David Álvarez Saltos et al.
Circulation
Mechanical Circulatory Support Devices
article

Abstract 4364999: Clinical Features And Hemodynamic Response of Microaxial Flow Pump Treatment in Cardiogenic Shock With or Without Myocardial Infarction

Matthew J. Pierce, Vladimir Shusterman, Shuojohn Li, Miguel David Álvarez Saltos, Matthew Griffin, Kuan‐Yu Lin, Gidon Salamatbad
article en

Abstract

Background: Recent DanGer-Shock trial demonstrated potential mortality benefit of microaxial flow pumps (mAFP) in select patients with acute myocardial infarction cardiogenic shock (AMI-CS). However, the clinical profile, hemodynamic response, and outcomes of mAFP use in non-acute myocardial infarction cardiogenic shock (nonAMI-CS) remain less well understood. Methods: Patients treated for cardiogenic shock between 2016 to 2022 with mAFP support (Impella 2.5, CP, 5.0, or 5.5) were retrospectively identified. Those with pulmonary artery catheter derived hemodynamics before and after implantation were included. Baseline hemodynamics were defined as the last recordings prior to device placement; post-implant hemodynamics were defined as the median of recordings within 24 hours after placement. Treatment success was defined as survival to discharge without ECMO escalation. Wilcoxon rank-sum and Chi-square tests were used for comparisons. Results: Of 110 patients included, 65 (59%) had AMI-CS and 45 (41%) had nonAMI-CS. Compared to AMI-CS, nonAMI-CS group had higher prevalence of chronic kidney disease, heart failure, atrial fibrillation, lower baseline ejection fraction and larger left ventricular diameter. High-capacity mAFP (Impella 5.0/5.5) were more frequently used in nonAMI-CS (29% vs. 5%, p<0.01) whereas AMI-CS received predominantly Impella CP (95%). The culprit vessels among AMI-CS patients were predominantly left-sided (51% LAD, 26% LCx, 12% left main, 9% RCA, 2% OM1). Baseline hemodynamics were similar between groups. Post-implantation, AMI-CS patients showed greater reductions in CVP (-40% vs. -31%, p = 0.04) and mPAP (-27% vs. -17%, p=0.04), achieving lower absolute CVP (9 vs. 12 mmHg, p < 0.01) and mPAP (25 vs. 29 mmHg, p = 0.04). In contrast, nonAMI-CS patients had greater improvement in cardiac index (CI) (+29% vs. +5%, p<0.01) and achieved a higher post-implant CI (2.45 vs. 1.93 L/min/m 2 , p < 0.01). Treatment success rates were not significantly different (52% AMI-CS vs. 36% nonAMI-CS, p=0.08). Conclusion: NonAMI-CS patients received more high-capacity mAFP and showed greater improvement in CI, while AMI-CS patients experienced more pronounced decongestion without significant increase in CI and a trend toward higher treatment success. These findings highlight decongestion as a potential prognostic signal in this patient cohort.

CirculationVol. 152(Suppl_3)
Northwell Health (US), North Shore University Hospital (US)
Openalex Percentile: Top 69%
Mechanical Circulatory Support Devices
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.