Abstract 4367166: A Multicenter Study of Detection of Pulmonary Hypertension Based on Point-of-Care 12- Lead ECG Data

Background: Pulmonary hypertension (PH) is a life-threatening disease affecting up to 1% of the global population. Diagnosis can be challenging and is often delayed due to the need for advanced imaging and invasive procedures. The use of artificial intelligence applied to ECGs (ECG-AI) has been shown to detect subtle patterns in voltage-time data and may be a valuable tool for the early detection of PH. Hypothesis and Purpose: To evaluate the performance of a previously trained, ECG-AI algorithm to detect PH (ECG-AI PH) using real-world data (RWD) collected in a multicenter, validation study. A joint primary hypothesis required sensitivity (Sn), specificity (Sp), positive predictive value (PPV), and negative predictive value (NPV) to exceed the null values of 76%, 70%, 10% and 90%. Study Design and Methods: This retrospective validation study was conducted at 5 geographically diverse U.S. health systems. Adult subjects were eligible for inclusion if they had a 12-lead ECG paired with an echocardiogram (Echo) in which tricuspid regurgitation velocity (TRV) was recorded, following presentation with dyspnea. Patients were classified according to echocardiographic criteria as either PH (PH+, TRV >3.4 m/s) or controls (PH-, TRV ≤2.8 m/s) to simulate the real-world use of ECG-AI, where a positive result could lead to a follow-up Echo. The study database was locked before processing the digital ECGs with ECG-AI PH. Performance was also estimated in a subset of subjects that later had a right heart catheterization using mPAP ≥ 20mmHg as the definition of PH. Results: A total of 14281 subjects (53% female, 63% aged 50+ years) met the inclusion criteria, including 3019 PH+ cases and 11262 PH- controls (Figure). Sn and Sp were 84.0% (95% CI: 82.6%, 85.3%) and 71.7% (95% CI: 70.9%, 72.6%), respectively. The positive and negative predictive values were 18.9% (95% CI: 18.4%, 19.4%) and 98.3% (95% CI: 98.1%, 98.4%), respectively, at 7.3% prevalence. Each endpoint met pre-defined performance criteria. In the subset of 1683 subjects with a follow up RHC, performance remained robust (Sn 85% (1155/1358); Sp 46% (151/325)). Conclusion: While ECG-AI PH was first developed as an investigational tool to detect PH, continued development as software as a medical device for clinical use demonstrated that the algorithm retained strong performance to detect PH in diverse, non-overlapping clinical settings and patient populations.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4367166
Primary Topic
ECG Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4367166: A Multicenter Study of Detection of Pulmonary Hypertension Based on Point-of-Care 12- Lead ECG Data

Jordan B. Strom, Hilary M. DuBrock, Benjamin Adam Steinberg, Rickey E. Carter et al.
Circulation
ECG Monitoring and Analysis
article

Abstract 4367166: A Multicenter Study of Detection of Pulmonary Hypertension Based on Point-of-Care 12- Lead ECG Data

Jordan B. Strom, Hilary M. DuBrock, Benjamin Adam Steinberg, Rickey E. Carter, Ambarish Pandey, Tyler Wagner, Anna R. Hemnes, Heather M. Alger, Mikolaj A. Wieczorek, Patrick W. Johnson, Jonathan W. Waks, Robert P. Frantz, Richa Agarwal, Sarah Hackett, Katherine Carlson, Paul Klugherz
article en

Abstract

Background: Pulmonary hypertension (PH) is a life-threatening disease affecting up to 1% of the global population. Diagnosis can be challenging and is often delayed due to the need for advanced imaging and invasive procedures. The use of artificial intelligence applied to ECGs (ECG-AI) has been shown to detect subtle patterns in voltage-time data and may be a valuable tool for the early detection of PH. Hypothesis and Purpose: To evaluate the performance of a previously trained, ECG-AI algorithm to detect PH (ECG-AI PH) using real-world data (RWD) collected in a multicenter, validation study. A joint primary hypothesis required sensitivity (Sn), specificity (Sp), positive predictive value (PPV), and negative predictive value (NPV) to exceed the null values of 76%, 70%, 10% and 90%. Study Design and Methods: This retrospective validation study was conducted at 5 geographically diverse U.S. health systems. Adult subjects were eligible for inclusion if they had a 12-lead ECG paired with an echocardiogram (Echo) in which tricuspid regurgitation velocity (TRV) was recorded, following presentation with dyspnea. Patients were classified according to echocardiographic criteria as either PH (PH+, TRV >3.4 m/s) or controls (PH-, TRV ≤2.8 m/s) to simulate the real-world use of ECG-AI, where a positive result could lead to a follow-up Echo. The study database was locked before processing the digital ECGs with ECG-AI PH. Performance was also estimated in a subset of subjects that later had a right heart catheterization using mPAP ≥ 20mmHg as the definition of PH. Results: A total of 14281 subjects (53% female, 63% aged 50+ years) met the inclusion criteria, including 3019 PH+ cases and 11262 PH- controls (Figure). Sn and Sp were 84.0% (95% CI: 82.6%, 85.3%) and 71.7% (95% CI: 70.9%, 72.6%), respectively. The positive and negative predictive values were 18.9% (95% CI: 18.4%, 19.4%) and 98.3% (95% CI: 98.1%, 98.4%), respectively, at 7.3% prevalence. Each endpoint met pre-defined performance criteria. In the subset of 1683 subjects with a follow up RHC, performance remained robust (Sn 85% (1155/1358); Sp 46% (151/325)). Conclusion: While ECG-AI PH was first developed as an investigational tool to detect PH, continued development as software as a medical device for clinical use demonstrated that the algorithm retained strong performance to detect PH in diverse, non-overlapping clinical settings and patient populations.

CirculationVol. 152(Suppl_3)
Beth Israel Deaconess Medical Center (US), Mayo Clinic (US), Harvard University (US), Duke University (US), University of Utah (US), Jacksonville College (US), WinnMed (US), Southwestern Medical Center (US), DNA Medicine Institute (United States) (US), Mayo Clinic in Florida (US), Southwestern Medical Center (US), The University of Texas Southwestern Medical Center (US)
Openalex Percentile: Top 52%
ECG Monitoring and Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.