Abstract 4362370: Impact of Coronovirus-19 on Physical Activity Measured by Cardiac Implanted Devices in a Veteran Population

Introduction: We investigated the impact of COVID-19 on physical activity (PA) in a veteran population with implanted cardiac devices by analyzing data from the devices’ embedded accelerometers. These accelerometers provide continuous, objective measurements of PA without requiring active patient participation or incurring additional costs, making them valuable for longitudinal monitoring and clinical research. Compared to pedometers, accelerometers have demonstrated superior accuracy and reliability in assessing physical activity levels. Methods: A total of 734 veterans with implanted Medtronic pacemakers or defibrillators at the Milwaukee VA Medical Center were screened for inclusion following IRB approval. Of these, 360 patients (aged 36–100 years; mean age 75.5 years) had continuous device-derived physical activity (PA) data available from 2018 through 2022. Data from 2018 and 2019 were categorized as the pre-COVID control period, while data from 2020, 2021, and 2022 were analyzed as the post-COVID study period. Results: There was a significant decline in physical activity (PA) recorded by the implanted cardiac devices between the pre-COVID and post-COVID periods (3.00 hr/day vs. 2.64 hr/day), representing a mean decrease of 0.37 hr/day (95% CI: 0.29 to 0.45; p < 0.0001). This downward trend in PA persisted even after public health restrictions were lifted. Conclusions: In a veteran population with implanted cardiac devices, physical activity significantly declined following the onset of COVID-19 and remained reduced through 2022, despite the lifting of public health restrictions. These findings highlight the lasting impact of the pandemic on functional status and underscore the value of device-based monitoring for long-term health surveillance. This has important implications for managing physical activity and health outcomes during future epidemics and pandemics.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4362370
Primary Topic
Cardiovascular Health and Risk Factors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4362370: Impact of Coronovirus-19 on Physical Activity Measured by Cardiac Implanted Devices in a Veteran Population

Sonia Kshatri, Amarjeet Kaur, Subhashish Agarwal, Dalip Singh et al.
Circulation
Cardiovascular Health and Risk Factors
article

Abstract 4362370: Impact of Coronovirus-19 on Physical Activity Measured by Cardiac Implanted Devices in a Veteran Population

Sonia Kshatri, Amarjeet Kaur, Subhashish Agarwal, Dalip Singh, H. N. Singh, Jashanpreet Kaur, Safar Ali Talari
article en

Abstract

Introduction: We investigated the impact of COVID-19 on physical activity (PA) in a veteran population with implanted cardiac devices by analyzing data from the devices’ embedded accelerometers. These accelerometers provide continuous, objective measurements of PA without requiring active patient participation or incurring additional costs, making them valuable for longitudinal monitoring and clinical research. Compared to pedometers, accelerometers have demonstrated superior accuracy and reliability in assessing physical activity levels. Methods: A total of 734 veterans with implanted Medtronic pacemakers or defibrillators at the Milwaukee VA Medical Center were screened for inclusion following IRB approval. Of these, 360 patients (aged 36–100 years; mean age 75.5 years) had continuous device-derived physical activity (PA) data available from 2018 through 2022. Data from 2018 and 2019 were categorized as the pre-COVID control period, while data from 2020, 2021, and 2022 were analyzed as the post-COVID study period. Results: There was a significant decline in physical activity (PA) recorded by the implanted cardiac devices between the pre-COVID and post-COVID periods (3.00 hr/day vs. 2.64 hr/day), representing a mean decrease of 0.37 hr/day (95% CI: 0.29 to 0.45; p < 0.0001). This downward trend in PA persisted even after public health restrictions were lifted. Conclusions: In a veteran population with implanted cardiac devices, physical activity significantly declined following the onset of COVID-19 and remained reduced through 2022, despite the lifting of public health restrictions. These findings highlight the lasting impact of the pandemic on functional status and underscore the value of device-based monitoring for long-term health surveillance. This has important implications for managing physical activity and health outcomes during future epidemics and pandemics.

CirculationVol. 152(Suppl_3)
Stevenson University (US), Georgia Institute of Technology (US), Medical College of Wisconsin (US), University School of Milwaukee (US), Milwaukee VA Medical Center (US), University of Wisconsin–Milwaukee (US)
Openalex Percentile: Top 52%
Cardiovascular Health and Risk Factors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.