Abstract 4370459: Dynamic PET Imaging Quantifies Absolute Measures of Calf Muscle Perfusion in a Porcine Model of Peripheral Endovascular Arterial Occlusion and PAD Patients with Claudication

Introduction: Peripheral artery disease (PAD) is an atherosclerotic disorder of the lower extremities promoting muscle ischemia. Our lab previously validated the use of fluorine-18 sodium fluoride ( 18 F-NaF) dynamic analog PET imaging for quantification of muscle perfusion in PAD. However, newer digital PET scanners with larger axial field-of-views could provide higher sensitivity detection of ischemia and broader perfusion assessment of the legs in PAD. This study sought to test the utility of a novel digital PET scanner for detecting muscle ischemia in a porcine model as well as PAD patients with claudication. Methods: Female Yorkshire pigs (N=6, 16.1 ± 4.0 kg) underwent unilateral iliac arterial occlusion via endovascular deployment of a covered stent and Amplatzer plug. On the day of occlusion, a 2.5-minute dynamic PET scan of the legs was performed following administration of 18 F-NaF (182.56 ± 9.55 MBq) using a large axial field-of-view digital PET scanner with bismuth germanate (BGO) crystals (GE Omni Legend). Co-registered CT images were acquired for attenuation correction and calf muscle segmentation. An image-derived arterial input was obtained from the abdominal aorta and time activity curves for the bilateral calves, to facilitate 1-tissue compartment modeling and calculation of skeletal muscle perfusion values (reported as ml/100g/min). The same dynamic PET approach was then translated to PAD patients (N = 21; 18 F-NaF dose: 310.43 ± 22.2 MBq), using the popliteal artery as an arterial input, to assess calf muscle perfusion. T-tests were used to compare perfusion values between ischemic and non-ischemic limbs in pigs and patients. Results: Digital subtraction angiography confirmed successful stent/plug deployment and arterial occlusion in pigs immediately post-occlusion (Fig. 1A). Dynamic PET/CT imaging revealed excellent count detection for kinetic modeling (Fig. 1B.1-2) and significant reductions in calf muscle perfusion between occluded and non-occluded limbs in the porcine model (p=0.031; Fig. 1C.1). Translation to PAD patients demonstrated significant reductions in calf perfusion in symptomatic versus asymptomatic limbs (p=0.039; Fig. 1C.2). Conclusions: Dynamic PET/CT imaging on emerging digital PET scanners allows for broader scan coverage, high-sensitivity detection of regional alterations in muscle ischemia in PAD, and provides unique opportunities for detection of disease and monitoring of treatment responses in PAD.

Authors

Institutions

Publication Details

Journal
Circulation
Published
2025-11-03
DOI
https://doi.org/10.1161/circ.152.suppl_3.4370459
Primary Topic
Peripheral Artery Disease Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Abstract 4370459: Dynamic PET Imaging Quantifies Absolute Measures of Calf Muscle Perfusion in a Porcine Model of Peripheral Endovascular Arterial Occlusion and PAD Patients with Claudication

Eleanor Rimmerman, Kumudha Musini, Kyle Shin, Mitchel R. Stacy et al.
Circulation
Peripheral Artery Disease Management
article

Abstract 4370459: Dynamic PET Imaging Quantifies Absolute Measures of Calf Muscle Perfusion in a Porcine Model of Peripheral Endovascular Arterial Occlusion and PAD Patients with Claudication

Eleanor Rimmerman, Kumudha Musini, Kyle Shin, Mitchel R. Stacy, Michael R. Go, Anjana Jayaraman, Patrick M. Tomko
article en

Abstract

Introduction: Peripheral artery disease (PAD) is an atherosclerotic disorder of the lower extremities promoting muscle ischemia. Our lab previously validated the use of fluorine-18 sodium fluoride ( 18 F-NaF) dynamic analog PET imaging for quantification of muscle perfusion in PAD. However, newer digital PET scanners with larger axial field-of-views could provide higher sensitivity detection of ischemia and broader perfusion assessment of the legs in PAD. This study sought to test the utility of a novel digital PET scanner for detecting muscle ischemia in a porcine model as well as PAD patients with claudication. Methods: Female Yorkshire pigs (N=6, 16.1 ± 4.0 kg) underwent unilateral iliac arterial occlusion via endovascular deployment of a covered stent and Amplatzer plug. On the day of occlusion, a 2.5-minute dynamic PET scan of the legs was performed following administration of 18 F-NaF (182.56 ± 9.55 MBq) using a large axial field-of-view digital PET scanner with bismuth germanate (BGO) crystals (GE Omni Legend). Co-registered CT images were acquired for attenuation correction and calf muscle segmentation. An image-derived arterial input was obtained from the abdominal aorta and time activity curves for the bilateral calves, to facilitate 1-tissue compartment modeling and calculation of skeletal muscle perfusion values (reported as ml/100g/min). The same dynamic PET approach was then translated to PAD patients (N = 21; 18 F-NaF dose: 310.43 ± 22.2 MBq), using the popliteal artery as an arterial input, to assess calf muscle perfusion. T-tests were used to compare perfusion values between ischemic and non-ischemic limbs in pigs and patients. Results: Digital subtraction angiography confirmed successful stent/plug deployment and arterial occlusion in pigs immediately post-occlusion (Fig. 1A). Dynamic PET/CT imaging revealed excellent count detection for kinetic modeling (Fig. 1B.1-2) and significant reductions in calf muscle perfusion between occluded and non-occluded limbs in the porcine model (p=0.031; Fig. 1C.1). Translation to PAD patients demonstrated significant reductions in calf perfusion in symptomatic versus asymptomatic limbs (p=0.039; Fig. 1C.2). Conclusions: Dynamic PET/CT imaging on emerging digital PET scanners allows for broader scan coverage, high-sensitivity detection of regional alterations in muscle ischemia in PAD, and provides unique opportunities for detection of disease and monitoring of treatment responses in PAD.

CirculationVol. 152(Suppl_3)
Nationwide Children's Hospital (US), Columbus State Community College (US), The Ohio State University (US)
Openalex Percentile: Top 50%
Peripheral Artery Disease Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.