An Experimental Study on the Thermal Runaway Characteristics of Single and Multiple Lithium-Ion Cells

This study experimentally investigated thermal runaway in NCA-type 18650 lithium-ion cells under single- and multiple-cell configurations. In single-cell tests, thermal runaway began at an average surface temperature of 186.9 ℃, with a maximum heat release rate (HRR) of 7.6 ± 0.8 kW, showing high reproducibility. In multiple-cell tests, the onset temperatures of the 2nd and 3rd cells rose to 207.8 ℃ and 211.9 ℃, influenced by thermal contact and heating rate, with propagation times of 54.7 s and 87.0 s. HRR data showed three distinct peaks during propagation, indicating that multiple-cell behavior cannot be explained by simply summing single-cell results. The severity of thermal runaway was strongly affected by venting duration and heating rate.

Authors

Publication Details

Journal
Fire Science and Engineering
Published
2025-10-31
DOI
https://doi.org/10.7731/kifse.fa9474e3
Primary Topic
Advanced Battery Technologies Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An Experimental Study on the Thermal Runaway Characteristics of Single and Multiple Lithium-Ion Cells

Hong-Seok Yun, Gyu-Bong Cho, Ho-Sik Han
Fire Science and Engineering
Advanced Battery Technologies Research
article

An Experimental Study on the Thermal Runaway Characteristics of Single and Multiple Lithium-Ion Cells

Hong-Seok Yun, Gyu-Bong Cho, Ho-Sik Han
article en

Abstract

This study experimentally investigated thermal runaway in NCA-type 18650 lithium-ion cells under single- and multiple-cell configurations. In single-cell tests, thermal runaway began at an average surface temperature of 186.9 ℃, with a maximum heat release rate (HRR) of 7.6 ± 0.8 kW, showing high reproducibility. In multiple-cell tests, the onset temperatures of the 2nd and 3rd cells rose to 207.8 ℃ and 211.9 ℃, influenced by thermal contact and heating rate, with propagation times of 54.7 s and 87.0 s. HRR data showed three distinct peaks during propagation, indicating that multiple-cell behavior cannot be explained by simply summing single-cell results. The severity of thermal runaway was strongly affected by venting duration and heating rate.

Fire Science and EngineeringVol. 39(5)
Openalex Percentile: Top 65%
Advanced Battery Technologies Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.