Validation of a Modified Sahli's Hemoglobin Method Using Automated CBC: A Feasibility Study for Point-of-Care Testing

Background: For rapid screening of anemia in the field on a mass scale, Hemoglobin is estimated by the Hemoglobin Colour Strip (HCS) method as per the WHO recommendation. However, this method does not provide precise measurements as several factors appear to contribute to incorrect readings. In this context, the modified method can be used in the field as a point-of-care assessment tool without any laboratory involvement, with more precise values close to those obtained in the laboratory-based automated CBC method(CBCA). Methods: 158 Students of both sexes in the age range of 18 to 25 years from the Department of Allied Health Sciences were randomly selected after obtaining their consent for this study. Venous blood was collected and hemoglobin was estimated by the HCS method, Conventional Sahli’s Method, and Sahli’s method with some modifications, and the result was compared with the gold standard for hemoglobin measurement tool, i.e. CBCA method. Results: It was found that modifications to the Sahlis method can improve its accuracy, as evidenced by the significant difference in Hb content between this method and the conventional Sahli’s method. It is also found that the reading obtained through this modified method is as close to the CBCA method. Discussion: Though the conventional Sahli’s method has so many advantages, it also has a good number of limitations. Moreover, in the conventional methodology, the reading of the acid hematin solution is noted till the color of the acid hematin solution matches the standard brown color glass of the comparator. But in reality, there is no single reading in which color just matches, which is purely based on color perception, which can vary and thereby is prone to a false low value than the real one. In such a condition, the recording of the reading under methodology is modified in such a way that the obtained value will be close to the real value compared with the autoanalyzer. Conclusion: From the present set of studies, it can be concluded that the modified Sahli’s method can be used as a more reliable tool for point-of-care largescale screening of anemia.

Authors

Institutions

Publication Details

Journal
Current Indian Science
Published
2025-10-29
DOI
https://doi.org/10.2174/012210299x413034251022214453
Primary Topic
Iron Metabolism and Disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of a Modified Sahli's Hemoglobin Method Using Automated CBC: A Feasibility Study for Point-of-Care Testing

Asim Kumar Basak
Current Indian Science
Iron Metabolism and Disorders
article

Validation of a Modified Sahli's Hemoglobin Method Using Automated CBC: A Feasibility Study for Point-of-Care Testing

Asim Kumar Basak
article en

Abstract

Background: For rapid screening of anemia in the field on a mass scale, Hemoglobin is estimated by the Hemoglobin Colour Strip (HCS) method as per the WHO recommendation. However, this method does not provide precise measurements as several factors appear to contribute to incorrect readings. In this context, the modified method can be used in the field as a point-of-care assessment tool without any laboratory involvement, with more precise values close to those obtained in the laboratory-based automated CBC method(CBCA). Methods: 158 Students of both sexes in the age range of 18 to 25 years from the Department of Allied Health Sciences were randomly selected after obtaining their consent for this study. Venous blood was collected and hemoglobin was estimated by the HCS method, Conventional Sahli’s Method, and Sahli’s method with some modifications, and the result was compared with the gold standard for hemoglobin measurement tool, i.e. CBCA method. Results: It was found that modifications to the Sahlis method can improve its accuracy, as evidenced by the significant difference in Hb content between this method and the conventional Sahli’s method. It is also found that the reading obtained through this modified method is as close to the CBCA method. Discussion: Though the conventional Sahli’s method has so many advantages, it also has a good number of limitations. Moreover, in the conventional methodology, the reading of the acid hematin solution is noted till the color of the acid hematin solution matches the standard brown color glass of the comparator. But in reality, there is no single reading in which color just matches, which is purely based on color perception, which can vary and thereby is prone to a false low value than the real one. In such a condition, the recording of the reading under methodology is modified in such a way that the obtained value will be close to the real value compared with the autoanalyzer. Conclusion: From the present set of studies, it can be concluded that the modified Sahli’s method can be used as a more reliable tool for point-of-care largescale screening of anemia.

Current Indian ScienceVol. 03
Techno India University (IN)
Openalex Percentile: Top 58%
Iron Metabolism and Disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.