Temperature and flow velocity dependency of biological screen-slot clogging in injection wells

Abstract Biological clogging in injection wells for ground water heat pump (GWHP) systems presents a significant operational challenge. The initial stage of clogging involves bacterial fouling attaching to the screen slots of the well pipes. However, few studies have systematically investigated its proliferation under different coupled conditions of injection water temperatures and horizontal groundwater flows. This study conducted a tank experiment to measure fouling weights on inserted steel plates under various test conditions involving two factors. Untreated groundwater from the bottom was supplied, and groundwater with adjusted temperature and dissolved oxygen from the top was introduced. The mass increase of iron-oxidation biofouling on the slotted steel plates was measured under varying conditions of injection water temperature and flow velocity through the slots. Results showed that higher flow velocities and elevated injection water temperatures increased biofouling mass. Specifically, the mass increased by up to 1.6 times due to differences in flow velocity and by up to 2.7 times due to differences in injection temperature. These results indicate that iron-oxidizing bacteria are activated by rising injection temperatures, as corroborated by previous studies, and that faster flow velocities provide a greater supply of substrates in the groundwater. Finally, the relationship between biofouling mass and injection temperatures was analyzed using an Arrhenius plot. This analysis yielded apparent activation energy values of 62.6 kJ/mol at a flow velocity of 1 m/d and 54.5 kJ/mol at a flow velocity of 0.1 m/d, with respective determination coefficients of 0.94 and 0.95.

Authors

Institutions

Publication Details

Journal
Geothermal Energy
Published
2025-11-03
DOI
https://doi.org/10.1186/s40517-025-00365-2
Primary Topic
Geothermal Energy Systems and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Temperature and flow velocity dependency of biological screen-slot clogging in injection wells

Yoshitaka Sakata, Katsunori Nagano, Hideki Sato, Shun Okihara
Geothermal Energy
Geothermal Energy Systems and Applications
article

Temperature and flow velocity dependency of biological screen-slot clogging in injection wells

Yoshitaka Sakata, Katsunori Nagano, Hideki Sato, Shun Okihara
article en

Abstract

Abstract Biological clogging in injection wells for ground water heat pump (GWHP) systems presents a significant operational challenge. The initial stage of clogging involves bacterial fouling attaching to the screen slots of the well pipes. However, few studies have systematically investigated its proliferation under different coupled conditions of injection water temperatures and horizontal groundwater flows. This study conducted a tank experiment to measure fouling weights on inserted steel plates under various test conditions involving two factors. Untreated groundwater from the bottom was supplied, and groundwater with adjusted temperature and dissolved oxygen from the top was introduced. The mass increase of iron-oxidation biofouling on the slotted steel plates was measured under varying conditions of injection water temperature and flow velocity through the slots. Results showed that higher flow velocities and elevated injection water temperatures increased biofouling mass. Specifically, the mass increased by up to 1.6 times due to differences in flow velocity and by up to 2.7 times due to differences in injection temperature. These results indicate that iron-oxidizing bacteria are activated by rising injection temperatures, as corroborated by previous studies, and that faster flow velocities provide a greater supply of substrates in the groundwater. Finally, the relationship between biofouling mass and injection temperatures was analyzed using an Arrhenius plot. This analysis yielded apparent activation energy values of 62.6 kJ/mol at a flow velocity of 1 m/d and 54.5 kJ/mol at a flow velocity of 0.1 m/d, with respective determination coefficients of 0.94 and 0.95.

Geothermal EnergyVol. 13(1)
Kanazawa University (JP), Hokkaido University (JP), Sanken Electric (Japan) (JP), National Institute of Technology, Tomakomai College (JP)
Openalex Percentile: Top 78%
Geothermal Energy Systems and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.