Output Estimation Method by Resonant Current Measurement for Filament Power Supply

This paper proposes a method for estimating the output voltage and current by measuring the low-voltage side resonant current of a series resonant converter operating in discontinuous conduction mode(DCM) for filament power supply applications. The proposed estimation method does not require sensing on the output side, so the high voltage insulation problem of the filament power supply sensing circuit in which the output is connected to the high voltage terminal of several tens of kV is solved. Through operation mode analysis, a resonant current equation for each mode was derived, and a method was derived to estimate the output voltage and current using peak value information. The proposed estimation method achieved an error rate of less than 1.5% through simulation, and it was verified that the estimation method could be effectively applied.

Authors

Publication Details

Journal
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
Published
2025-10-31
DOI
https://doi.org/10.5207/jieie.2025.39.5.337
Primary Topic
Advanced DC-DC Converters
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Output Estimation Method by Resonant Current Measurement for Filament Power Supply

Seungho Song, P. Kim
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
Advanced DC-DC Converters
article

Output Estimation Method by Resonant Current Measurement for Filament Power Supply

Seungho Song, P. Kim
article en

Abstract

This paper proposes a method for estimating the output voltage and current by measuring the low-voltage side resonant current of a series resonant converter operating in discontinuous conduction mode(DCM) for filament power supply applications. The proposed estimation method does not require sensing on the output side, so the high voltage insulation problem of the filament power supply sensing circuit in which the output is connected to the high voltage terminal of several tens of kV is solved. Through operation mode analysis, a resonant current equation for each mode was derived, and a method was derived to estimate the output voltage and current using peak value information. The proposed estimation method achieved an error rate of less than 1.5% through simulation, and it was verified that the estimation method could be effectively applied.

Journal of the Korean Institute of Illuminating and Electrical Installation EngineersVol. 39(5)
Openalex Percentile: Top 68%
Advanced DC-DC Converters
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.