Correlation between left ventricular outflow tract-velocity time integral (LVOT-VTI) and transthoracic echocardiographic pulmonary to left atrial ratio (e-PLAR) in critically ill patients as a predictor of fluid responsiveness

Abstract Background Assessing fluid responsiveness in critically ill patients remains a significant clinical challenge. This study was designed to evaluate whether the echocardiographic pulmonary-to-left atrial ratio (e-PLAR), calculated as TR Vmax/ mitral (E/E`), can predict fluid responsiveness in critically ill patients, and to compare its predictive value with that of left ventricular outflow tract velocity time integral (LVOT-VTI) variability. Methods A prospective cohort study was conducted involving 63 critically ill patients requiring fluid resuscitation. Both the TR Vmax/mitral (E/E`) and LVOT-VTI variability were measured before and after administering a mini-fluid challenge (100 ml). Patients were classified as fluid responders if their mean LVOT-VTI variability exceeded 15%. Results Of the 63 patients enrolled, 46 (73%) were identified as fluid responders, while 17 (27%) were non-responders. LVOT-VTI variability predicted fluid responsiveness with a cutoff value of less than 20 cm, demonstrating a sensitivity of 84% and a specificity of 88.6% ( P < 0.005). The TR Vmax/Mitral (E/E`) did not reliably predict fluid responsiveness, with an area under the ROC curve of 0.4 and a P value of 0.8. Notably, patients with a TRV max/(E:E`) ratio greater than 0.3 m/s showed a more significant change following the fluid challenge ( P = 0.02). Conclusion The findings indicate that the TRVmax/(E:E’) ratio is not a reliable predictor of fluid responsiveness in critically ill patients and does not correlate with mortality or ICU length of stay. In contrast, LVOT-VTI variability remains a more effective tool for assessing fluid responsiveness in this patient population.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Critical Care Medicine
Published
2025-11-02
DOI
https://doi.org/10.1007/s44349-025-00031-3
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Correlation between left ventricular outflow tract-velocity time integral (LVOT-VTI) and transthoracic echocardiographic pulmonary to left atrial ratio (e-PLAR) in critically ill patients as a predictor of fluid responsiveness

Salah O.E. Arafa, Dina Zeid, Mamdouh Afify, Mai Adel Sahbal
The Egyptian Journal of Critical Care Medicine
Hemodynamic Monitoring and Therapy
article

Correlation between left ventricular outflow tract-velocity time integral (LVOT-VTI) and transthoracic echocardiographic pulmonary to left atrial ratio (e-PLAR) in critically ill patients as a predictor of fluid responsiveness

Salah O.E. Arafa, Dina Zeid, Mamdouh Afify, Mai Adel Sahbal
article en

Abstract

Abstract Background Assessing fluid responsiveness in critically ill patients remains a significant clinical challenge. This study was designed to evaluate whether the echocardiographic pulmonary-to-left atrial ratio (e-PLAR), calculated as TR Vmax/ mitral (E/E`), can predict fluid responsiveness in critically ill patients, and to compare its predictive value with that of left ventricular outflow tract velocity time integral (LVOT-VTI) variability. Methods A prospective cohort study was conducted involving 63 critically ill patients requiring fluid resuscitation. Both the TR Vmax/mitral (E/E`) and LVOT-VTI variability were measured before and after administering a mini-fluid challenge (100 ml). Patients were classified as fluid responders if their mean LVOT-VTI variability exceeded 15%. Results Of the 63 patients enrolled, 46 (73%) were identified as fluid responders, while 17 (27%) were non-responders. LVOT-VTI variability predicted fluid responsiveness with a cutoff value of less than 20 cm, demonstrating a sensitivity of 84% and a specificity of 88.6% ( P < 0.005). The TR Vmax/Mitral (E/E`) did not reliably predict fluid responsiveness, with an area under the ROC curve of 0.4 and a P value of 0.8. Notably, patients with a TRV max/(E:E`) ratio greater than 0.3 m/s showed a more significant change following the fluid challenge ( P = 0.02). Conclusion The findings indicate that the TRVmax/(E:E’) ratio is not a reliable predictor of fluid responsiveness in critically ill patients and does not correlate with mortality or ICU length of stay. In contrast, LVOT-VTI variability remains a more effective tool for assessing fluid responsiveness in this patient population.

The Egyptian Journal of Critical Care MedicineVol. 12(1)
Cairo University (EG)
Openalex Percentile: Top 50%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Correlation between left ventricular outflow tract-velocity time integral (LVOT-VTI) and transthoracic echocardiographic pulmonary to left atrial ratio (e-PLAR) in critically ill patients as a predictor of fluid responsiveness — Salah O.E. Arafa, Dina Zeid, et al. · The Egyptian Journal of Critical Care Medicine (2025) | TGRS Research Map | TGRS