Highly selective and sensitive uric acid sensor based on a self-assembled CdS/CdIn <sub>2</sub> S <sub>4</sub> heterojunction

Uric acid (UA) detection plays a crucial role in the early diagnosis and treatment of diseases linked with hypo-/hyper-uricemia. Electrochemical sensing technology has attracted widespread attention due to its fast response, high sensitivity, portability and ease of operation. However, regular electrochemical UA sensors remarkably suffer from unfavorable selectivity, high cost, complexity of fabrication, and over-reliance on blood sampling. Herein, we present a hetero-structured CdS/CdIn<sub>2</sub>S<sub>4</sub>-modified screen-printed carbon electrode (SPCE) capable of achieving accessible and cost-effective UA determination <i>via</i> a facile hydrothermal self-assembly method, which enhances electrocatalytic activity through optimized band structures and abundant surface sites. Benefiting from the synergy of componential optimization and heterojunction design, the CdS/CdIn<sub>2</sub>S<sub>4</sub>/SPCE-based electrochemical UA sensor (CEUS) achieves a high sensitivity of 717.5 μA mM<sup>-1</sup> cm<sup>-2</sup>, high selectivity, a wide linear range of 0.5-1000 μM and a low detection limit (LOD) of 0.12 μM. Density functional theory (DFT) calculations reveal that the heterojunction interface facilitates electron transfer and promotes hydroxyl radical generation to enhance UA oxidation. Furthermore, food hygiene inspection and gout monitoring are accomplished by probing the UA level in both fish foods and biological fluids, including serum, urine and sweat, obtaining satisfactory accuracy and anti-interference traits. This work provides a promising avenue for the development of ultrasensitive wearable nonenzymatic sweat biosensors for personalized health assessment and food-freshness monitoring.

Authors

Institutions

Publication Details

Journal
Nanoscale
Published
2025-01-01
DOI
https://doi.org/10.1039/d5nr03132j
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Highly selective and sensitive uric acid sensor based on a self-assembled CdS/CdIn 2 S 4 heterojunction

Yuanjie Su, Min Yang, Xin Zhao, Yang‐Bao Miao et al.
Nanoscale
Electrochemical sensors and biosensors
article

Highly selective and sensitive uric acid sensor based on a self-assembled CdS/CdIn 2 S 4 heterojunction

Yuanjie Su, Min Yang, Xin Zhao, Yang‐Bao Miao, Jing Li, Lei Zhu, Bei Li, Guangzhong Xie, Qiuping Zhang
article en

Abstract

Uric acid (UA) detection plays a crucial role in the early diagnosis and treatment of diseases linked with hypo-/hyper-uricemia. Electrochemical sensing technology has attracted widespread attention due to its fast response, high sensitivity, portability and ease of operation. However, regular electrochemical UA sensors remarkably suffer from unfavorable selectivity, high cost, complexity of fabrication, and over-reliance on blood sampling. Herein, we present a hetero-structured CdS/CdIn<sub>2</sub>S<sub>4</sub>-modified screen-printed carbon electrode (SPCE) capable of achieving accessible and cost-effective UA determination <i>via</i> a facile hydrothermal self-assembly method, which enhances electrocatalytic activity through optimized band structures and abundant surface sites. Benefiting from the synergy of componential optimization and heterojunction design, the CdS/CdIn<sub>2</sub>S<sub>4</sub>/SPCE-based electrochemical UA sensor (CEUS) achieves a high sensitivity of 717.5 μA mM<sup>-1</sup> cm<sup>-2</sup>, high selectivity, a wide linear range of 0.5-1000 μM and a low detection limit (LOD) of 0.12 μM. Density functional theory (DFT) calculations reveal that the heterojunction interface facilitates electron transfer and promotes hydroxyl radical generation to enhance UA oxidation. Furthermore, food hygiene inspection and gout monitoring are accomplished by probing the UA level in both fish foods and biological fluids, including serum, urine and sweat, obtaining satisfactory accuracy and anti-interference traits. This work provides a promising avenue for the development of ultrasensitive wearable nonenzymatic sweat biosensors for personalized health assessment and food-freshness monitoring.

NanoscaleVol. 17(44)
University of Electronic Science and Technology of China (CN), Wuhan University of Technology (CN), Sichuan Academy of Medical Sciences & Sichuan Provincial People's Hospital (CN), National Engineering Research Center of Electromagnetic Radiation Control Materials (CN), Chengdu Normal University (CN)
Openalex Percentile: Top 68%
Electrochemical sensors and biosensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.