Wearable system for the measurement of gait cycle kinematic and kinetic signals

Gait analysis is a fundamental tool in biomechanics and rehabilitation, as it evaluates human movements' kinematic and kinetic behavior. For this reason, high-precision devices have been developed. However, these require controlled environments, which generates a deficiency in the capacity of studies related to gait analysis in outdoor and indoor scenarios. Therefore, this article describes the development and testing of a wearable system to measure gait cycle kinematic and kinetic parameters. The methodology for the development of the system includes the assembly of modules with commercial surface electromyography (sEMG) sensors and inertial measurement sensors, as well as the use of instrumented insoles with force-resistive sensors, and the design of the software to acquire, process, visualize, and store the data. The system design considers portability, rechargeable battery power supply, wireless communication, acquisition speed suitable for kinematic and kinetic signals, and compact size. Also, it allows simultaneous assessment of sEMG activity, hip and knee joint angles, and plantar pressure distribution, using a wireless connection via Wi-Fi and user datagram protocol for data transmission with a synchronization accuracy of 576 <i>μ</i>s, data loss of 0.8%, and autonomy of 167 min of continuous operation, enabling uninterrupted data acquisition for gait analysis. To demonstrate its performance, the system was tested on 10 subjects without any neuromusculoskeletal pathology in indoor and outdoor environments, evaluating relevant parameters that facilitate a comprehensive analysis of gait in various contexts. The system offers a reliable, versatile, and affordable alternative for gait assessment in outdoor and indoor environments.

Authors

Institutions

Publication Details

Journal
Wearable Technologies
Published
2025-01-01
DOI
https://doi.org/10.1017/wtc.2025.10032
Primary Topic
Muscle activation and electromyography studies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Wearable system for the measurement of gait cycle kinematic and kinetic signals

Mariana Ballesteros, David Cruz‐Ortiz, Manuela Gómez-Correa, Mariana Alegria
Wearable Technologies
Muscle activation and electromyography studies
article

Wearable system for the measurement of gait cycle kinematic and kinetic signals

Mariana Ballesteros, David Cruz‐Ortiz, Manuela Gómez-Correa, Mariana Alegria
article en

Abstract

Gait analysis is a fundamental tool in biomechanics and rehabilitation, as it evaluates human movements' kinematic and kinetic behavior. For this reason, high-precision devices have been developed. However, these require controlled environments, which generates a deficiency in the capacity of studies related to gait analysis in outdoor and indoor scenarios. Therefore, this article describes the development and testing of a wearable system to measure gait cycle kinematic and kinetic parameters. The methodology for the development of the system includes the assembly of modules with commercial surface electromyography (sEMG) sensors and inertial measurement sensors, as well as the use of instrumented insoles with force-resistive sensors, and the design of the software to acquire, process, visualize, and store the data. The system design considers portability, rechargeable battery power supply, wireless communication, acquisition speed suitable for kinematic and kinetic signals, and compact size. Also, it allows simultaneous assessment of sEMG activity, hip and knee joint angles, and plantar pressure distribution, using a wireless connection via Wi-Fi and user datagram protocol for data transmission with a synchronization accuracy of 576 <i>μ</i>s, data loss of 0.8%, and autonomy of 167 min of continuous operation, enabling uninterrupted data acquisition for gait analysis. To demonstrate its performance, the system was tested on 10 subjects without any neuromusculoskeletal pathology in indoor and outdoor environments, evaluating relevant parameters that facilitate a comprehensive analysis of gait in various contexts. The system offers a reliable, versatile, and affordable alternative for gait assessment in outdoor and indoor environments.

Wearable TechnologiesVol. 6
Instituto Politécnico Nacional (MX)
Openalex Percentile: Top 69%
Muscle activation and electromyography studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.