Feasibility of Aorto-uni-iliac Endovascular Aortic Repair Using the Gore Excluder for Abdominal Aortic Aneurysm

<b>Purpose:</b> To evaluate the feasibility of aorto-uni-iliac endovascular aortic repair using the Gore Excluder in selected patients. <b>Material and Methods:</b> This retrospective study reviewed five cases of aorto-uni-iliac endovascular aortic repair for abdominal aortic aneurysm using the Gore Excluder between January 2014 and January 2024. Patient demographics, procedural details, and postoperative outcomes were evaluated. Study endpoints included technical success, overall survival, aneurysm sac changes, endoleak occurrence, secondary interventions, and aneurysm-related death to evaluate feasibility and mid-term durability. Technical success was defined as successful stent graft deployment without conversion to open repair. <b>Results:</b> The cohort included one elective case in which a dedicated aorto-uni-iliac device was deemed unsuitable, three cases converted intraoperatively from bifurcated to aorto-uni-iliac configuration, and one case in which the dedicated device was unavailable. The aorto-uni-iliac configuration was achieved through off-label use of aortic extenders or an upside-down contralateral leg. All cases were technically successful. Three cases were emergency procedures. All cases required femoro-femoral crossover bypass. Slight type III endoleaks were detected in two cases on completion aortography but had resolved on postoperative computed tomography on days 11 and 16, respectively. No type III endoleaks were observed in any case during follow-up. No aneurysm-related deaths occurred. Over a median follow-up of 35 months (range: 1-62; excluding one same-day death), no sac enlargement was observed, suggesting acceptable durability. Median overall survival was 1,100 days (range: 0-1,966). <b>Conclusions:</b> Aorto-uni-iliac endovascular aortic repair using the Gore Excluder for abdominal aortic aneurysm is feasible when dedicated aorto-uni-iliac devices are unavailable or unsuitable, particularly in emergencies.

Authors

Institutions

Publication Details

Journal
Interventional Radiology
Published
2025-10-20
DOI
https://doi.org/10.22575/interventionalradiology.2025-0030
Primary Topic
Aortic aneurysm repair treatments
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Feasibility of Aorto-uni-iliac Endovascular Aortic Repair Using the Gore Excluder for Abdominal Aortic Aneurysm

Hiroshi Ikeno, Kazunori Koyama, Nobuhiko Ogawa, Kotaro Yoshida et al.
Interventional Radiology
Aortic aneurysm repair treatments
article

Feasibility of Aorto-uni-iliac Endovascular Aortic Repair Using the Gore Excluder for Abdominal Aortic Aneurysm

Hiroshi Ikeno, Kazunori Koyama, Nobuhiko Ogawa, Kotaro Yoshida, Toru Yamamoto, Jun Yoshikawa, Shintaro Takago, Takumi Sugiura, Shiro Miyayama, Akira Yokka, Satoru Nishida
article en

Abstract

<b>Purpose:</b> To evaluate the feasibility of aorto-uni-iliac endovascular aortic repair using the Gore Excluder in selected patients. <b>Material and Methods:</b> This retrospective study reviewed five cases of aorto-uni-iliac endovascular aortic repair for abdominal aortic aneurysm using the Gore Excluder between January 2014 and January 2024. Patient demographics, procedural details, and postoperative outcomes were evaluated. Study endpoints included technical success, overall survival, aneurysm sac changes, endoleak occurrence, secondary interventions, and aneurysm-related death to evaluate feasibility and mid-term durability. Technical success was defined as successful stent graft deployment without conversion to open repair. <b>Results:</b> The cohort included one elective case in which a dedicated aorto-uni-iliac device was deemed unsuitable, three cases converted intraoperatively from bifurcated to aorto-uni-iliac configuration, and one case in which the dedicated device was unavailable. The aorto-uni-iliac configuration was achieved through off-label use of aortic extenders or an upside-down contralateral leg. All cases were technically successful. Three cases were emergency procedures. All cases required femoro-femoral crossover bypass. Slight type III endoleaks were detected in two cases on completion aortography but had resolved on postoperative computed tomography on days 11 and 16, respectively. No type III endoleaks were observed in any case during follow-up. No aneurysm-related deaths occurred. Over a median follow-up of 35 months (range: 1-62; excluding one same-day death), no sac enlargement was observed, suggesting acceptable durability. Median overall survival was 1,100 days (range: 0-1,966). <b>Conclusions:</b> Aorto-uni-iliac endovascular aortic repair using the Gore Excluder for abdominal aortic aneurysm is feasible when dedicated aorto-uni-iliac devices are unavailable or unsuitable, particularly in emergencies.

Interventional RadiologyVol. 10(0)
Fukui Prefectural Hospital (JP), Fukui-ken Saiseikai Hospital (JP)
Openalex Percentile: Top 54%
Aortic aneurysm repair treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.