The perfect match: Aortic valve sizing to maximize hemodynamic performance and survival

<h2>Abstract</h2><h3>Objective</h3> We assessed the value of using a size ratio of implanted valve opening diameter to native annular diameter to determine postoperative hemodynamics and survival after surgical aortic valve replacement. <h3>Methods</h3> In total, 1519 patients from 3 trials had a preoperative computed tomography scan. A size ratio was created using the implanted valve's Ebels' prosthetic valve−derived effective diameter (ED) and the patient's computed tomography perimeter−derived native annular diameter (CTD). Restricted cubic spline curves showed the association between size ratio and hemodynamic performance. Patients were divided into 3 ratio groups: <80%, 80% to 90%, and >90%. Hemodynamic performance was evaluated yearly for 5 years. Multivariable proportional hazard regression examined the association between size ratio and 5-year survival. <h3>Results</h3> Mean valve gradient, peak velocity, effective orifice area (EOA), indexed EOA, dimensionless velocity index, and prosthesis-patient mismatch were significantly better advancing from the 80% to the 90% groups (<i>P</i> < .001). The >90% group had a single-digit mean valve gradient, peak velocity ≤2.0 m/s, EOA ≥2.0 cm<sup>2</sup>, indexed EOA ≥1.0 cm<sup>2</sup>/m<sup>2</sup>, dimensionless velocity index ≥0.5, and no prosthesis-patient mismatch ≥85% at 1 and 5 years. Size ratio was an independent predictor of mortality with survival benefit through 5 years (80%-90% vs <80%, hazard ratio, 0.752; 95% confidence interval, 0.611-0.927, <i>P</i> = .008; >90% vs <80%, hazard ratio, 0.712; 95% confidence interval, 0.506-1.001, <i>P</i> = .05). <h3>Conclusions</h3> An ED/CTD size ratio >90% is associated with optimal postoperative hemodynamic performance and improved 5-year survival. Preoperative ED/CTD ratio provides the ideal implanted valve size and helps determine if annular enlargement is necessary.

Authors

Institutions

Publication Details

Journal
JTCVS structural and endovascular.
Published
2025-10-31
DOI
https://doi.org/10.1016/j.xjse.2025.100088
Citations
1
Primary Topic
Cardiac Valve Diseases and Treatments
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The perfect match: Aortic valve sizing to maximize hemodynamic performance and survival

Bo Yang, Julie A. Linick, Robert B. Hawkins, Shinichi Fukuhara et al.
1 citations
JTCVS structural and endovascular.
Cardiac Valve Diseases and Treatments
1.39
article

The perfect match: Aortic valve sizing to maximize hemodynamic performance and survival

Bo Yang, Julie A. Linick, Robert B. Hawkins, Shinichi Fukuhara, Himanshu J. Patel, Barbara C.S. Hamilton, Stanley Chetcuti, Michael J. Reardon, Sachin S. Goel, Michael J. Boulware, Shuzhen Li, Gorav Ailawadi, G. Michael Deeb, Mikhale Grundtner
article en
1 citations

Abstract

<h2>Abstract</h2><h3>Objective</h3> We assessed the value of using a size ratio of implanted valve opening diameter to native annular diameter to determine postoperative hemodynamics and survival after surgical aortic valve replacement. <h3>Methods</h3> In total, 1519 patients from 3 trials had a preoperative computed tomography scan. A size ratio was created using the implanted valve's Ebels' prosthetic valve−derived effective diameter (ED) and the patient's computed tomography perimeter−derived native annular diameter (CTD). Restricted cubic spline curves showed the association between size ratio and hemodynamic performance. Patients were divided into 3 ratio groups: <80%, 80% to 90%, and >90%. Hemodynamic performance was evaluated yearly for 5 years. Multivariable proportional hazard regression examined the association between size ratio and 5-year survival. <h3>Results</h3> Mean valve gradient, peak velocity, effective orifice area (EOA), indexed EOA, dimensionless velocity index, and prosthesis-patient mismatch were significantly better advancing from the 80% to the 90% groups (<i>P</i> < .001). The >90% group had a single-digit mean valve gradient, peak velocity ≤2.0 m/s, EOA ≥2.0 cm<sup>2</sup>, indexed EOA ≥1.0 cm<sup>2</sup>/m<sup>2</sup>, dimensionless velocity index ≥0.5, and no prosthesis-patient mismatch ≥85% at 1 and 5 years. Size ratio was an independent predictor of mortality with survival benefit through 5 years (80%-90% vs <80%, hazard ratio, 0.752; 95% confidence interval, 0.611-0.927, <i>P</i> = .008; >90% vs <80%, hazard ratio, 0.712; 95% confidence interval, 0.506-1.001, <i>P</i> = .05). <h3>Conclusions</h3> An ED/CTD size ratio >90% is associated with optimal postoperative hemodynamic performance and improved 5-year survival. Preoperative ED/CTD ratio provides the ideal implanted valve size and helps determine if annular enlargement is necessary.

JTCVS structural and endovascular.Vol. 8
Houston Methodist (US), University of Michigan (US), Medtronic (Ireland) (IE)
Openalex Percentile: Top 14%
Cardiac Valve Diseases and Treatments
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.