Guiding Control by Magnetic Guiding Device for Capsule Endoscope

The purpose of this paper is quantitative evaluation of guiding control by magnetic guiding device for capsule endoscope (CE). In this report, the magnetic force for a CE manipulating a magnetic guiding device is calculated using a transient response analysis with a finite element analysis software. It was found that the maximum value of magnetic force is defined by the distance between the CE and the magnetic guide device. This paper proposes an approximation for the maximum value as a function of the distance if the distance is between 0.06 m and 0.12 m. From experimental results, the guide control by magnetic guide device is successfully confirmed at the distance of 100 mm. It is noted that the movement speed of the magnetic guide device should be less than 0.066 m/s.

Authors

Institutions

Publication Details

Journal
IEEJ Transactions on Fundamentals and Materials
Published
2025-10-31
DOI
https://doi.org/10.1541/ieejfms.145.354
Primary Topic
Gastrointestinal Bleeding Diagnosis and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Guiding Control by Magnetic Guiding Device for Capsule Endoscope

Kunihisa Tashiro, Naoki Ohmiya, Naoki Morikawa
IEEJ Transactions on Fundamentals and Materials
Gastrointestinal Bleeding Diagnosis and Treatment
article

Guiding Control by Magnetic Guiding Device for Capsule Endoscope

Kunihisa Tashiro, Naoki Ohmiya, Naoki Morikawa
article en

Abstract

The purpose of this paper is quantitative evaluation of guiding control by magnetic guiding device for capsule endoscope (CE). In this report, the magnetic force for a CE manipulating a magnetic guiding device is calculated using a transient response analysis with a finite element analysis software. It was found that the maximum value of magnetic force is defined by the distance between the CE and the magnetic guide device. This paper proposes an approximation for the maximum value as a function of the distance if the distance is between 0.06 m and 0.12 m. From experimental results, the guide control by magnetic guide device is successfully confirmed at the distance of 100 mm. It is noted that the movement speed of the magnetic guide device should be less than 0.066 m/s.

IEEJ Transactions on Fundamentals and MaterialsVol. 145(11)
Shinshu University (JP), Fujita Health University (JP)
Openalex Percentile: Top 55%
Gastrointestinal Bleeding Diagnosis and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.