Measurement error of cardiac output determined by nitrous oxide rebreathing and impedance cardiography in healthy adults
Cardiac output (Q̇) is a fundamental physiological variable but remains challenging to measure. Exercise Q̇ is commonly measured by inert gas rebreathing using acetylene or nitrous oxide (Q̇<sub>N<sub>2</sub>O-IGR</sub>) and impedance cardiography (Q̇<sub>IC</sub>), but device measurement error has not been assessed at different workloads or in females. This study determined the precision of Q̇<sub>N<sub>2</sub>O-IGR</sub> (Innocor, COSMED Inc., USA) and Q̇<sub>IC</sub> (Physioflow Enduro, Manatec Biomedical, France) in duplicate in 60 adults (30 females; 22 ± 5 years; V̇O<sub>2max</sub>: 41.2 ± 8.6 mL<sup>.</sup>kg<sup>-1.</sup>min<sup>-1</sup>) during upright rest and cycling at 50 W and 90% peak power output (PPO) (277 ± 71 W). Measurement variance was higher for Q̇<sub>N<sub>2</sub>O-IGR</sub> vs. Q̇<sub>IC</sub> (<i>p</i> < 0.0001), at 90% PPO compared to 50 W at rest (<i>p</i> < 0.001), and in males vs. females at 50 W with Q̇<sub>N<sub>2</sub>O-IGR</sub> (<i>p</i> = 0.005). At rest the typical error (TE), coefficient of variation (CV), and intraclass correlation (ICC) were 0.6 L/min (12.4%), 11.6 ± 8.5%, and 0.75 [0.62-0.82] for Q̇<sub>N<sub>2</sub>O-IGR</sub> and 0.4 L/min (6.9%), 7.5 ± 8.4, and 0.87 [0.79-0.92] for Q̇<sub>IC</sub>. At 50 W, the TE, CV, and ICC were 0.8 L/min (7.7%), 5.4 ± 5.8%, and 0.79 [0.68-0.87] for Q̇<sub>N<sub>2</sub>O-IGR</sub> and 0.5 L/min (5.6%), 3.7 ± 3.8%, and 0.85 [0.76-0.91] for Q̇<sub>IC</sub>. At 90% PPO, TE, CV, and ICC were 1.2 L/min (7.5%), 5.4 ± 4.3%, and 0.89 [0.82-0.93] for Q̇<sub>N<sub>2</sub>O-IGR</sub> and 0.7 L/min (4.0%), 5.0 ± 3.2%, 0.96 [0.93-0.98] for Q̇<sub>IC</sub>. Duplicate Q̇<sub>N<sub>2</sub>O-IGR</sub> differed up to ∼4 L/min (38%) and Q̇<sub>IC</sub> ∼3 L/min (24%). In conclusion, group-level measurement precision was generally better for Q̇<sub>IC</sub> than Q̇<sub>N<sub>2</sub>O-IGR</sub> but depended on workload and sex. Duplicate Q̇<sub>N<sub>2</sub>O-IGR</sub> and Q̇<sub>IC</sub> differed substantially; therefore, repeat measures are important.
Authors
- Philip J. Millar (ORCID: https://orcid.org/0000-0002-2177-1061)
- G. Romano (ORCID: https://orcid.org/0000-0002-3051-7612)
- Jamie F. Burr (ORCID: https://orcid.org/0000-0002-5449-3352)
- Devin G. McCarthy (ORCID: https://orcid.org/0000-0002-7326-7705)
- Tanvir S Matharu
- Jake J. Thiessen (ORCID: https://orcid.org/0009-0004-1177-544X)
Institutions
- University of Guelph-Humber (CA)
- University of Guelph (CA)
Publication Details
- Journal
- Applied Physiology Nutrition and Metabolism
- Published
- 2025-01-01
- DOI
- https://doi.org/10.1139/apnm-2025-0234
- Primary Topic
- Hemodynamic Monitoring and Therapy
- Type
- article
- Field-Weighted Citation Impact
- 0.00