Evaluation of the new blood-pool CT contrast agent VivoVist in mouse models

Small animal CT imaging provides high resolution imaging of bone structure, lungs, and gross anatomy. However, it is limited in its ability to provide high soft tissue contrast. Several blood pool CT contrast agents have been developed to enhance vascular and tissue contrast for preclinical imaging with varying enhancement capabilities. VivoVistTM is the most recent commercially available blood pool CT contrast agent for preclinical applications. This study independently evaluated its radiopacity and tissue enhancement compared to two existing preclinical CT contrast agents, Mvivo-Au, and Fenestra-HDVC. Healthy nude mice were administered one of the three contrast agents. CT imaging was performed before and at 5 minutes, 1 hour, 4 hours, 24 hours, 48 hours, 96 hours, and 7 days post-injection. Tissue intensity and the enhancement ratio relative to pre-injection levels were quantified for each contrast agent at each time point. VivoVist demonstrated significantly higher blood enhancement compared to Mvivo-Au and Fenestra-HDVC at 5 minutes and 1 hour post-injection. However, the enhancement at 4 hours and later time points was inferior to that of Mvivo-Au. VivoVist exhibited the fastest blood clearance among the three contrast agents, with a blood half-life of 3.1 hours and was largely cleared from the blood by 24 hours post-injection. In CT imaging after 24 hours post-injection, VivoVist showed the highest liver enhancement, which remained high over the 7-day imaging period. Biodistribution assessment showed that the splenic uptake of VivoVist was extremely high. Histological examination of the tissues identified abundant contrast agent accumulation in the liver and spleen. No overt pathological changes were observed in either organ one month after the injection of VivoVist. Overall, the evaluation confirmed that VivoVist is an effective CT contrast agent for vascular and liver imaging with low toxicity. However, its relatively short blood half-life limits its use as a vascular contrast agent for a prolonged period.

Authors

Institutions

Publication Details

Journal
PLoS ONE
Published
2025-10-31
DOI
https://doi.org/10.1371/journal.pone.0335025
Primary Topic
Ultrasound and Hyperthermia Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the new blood-pool CT contrast agent VivoVist in mouse models

Spencer V. Thompson, Gregory K. Wilkerson, Jonathan E. Frank, Eric W. Livingston et al.
PLoS ONE
Ultrasound and Hyperthermia Applications
article

Evaluation of the new blood-pool CT contrast agent VivoVist in mouse models

Spencer V. Thompson, Gregory K. Wilkerson, Jonathan E. Frank, Eric W. Livingston, Hong Yuan, Jean-Felix Presler
article en

Abstract

Small animal CT imaging provides high resolution imaging of bone structure, lungs, and gross anatomy. However, it is limited in its ability to provide high soft tissue contrast. Several blood pool CT contrast agents have been developed to enhance vascular and tissue contrast for preclinical imaging with varying enhancement capabilities. VivoVistTM is the most recent commercially available blood pool CT contrast agent for preclinical applications. This study independently evaluated its radiopacity and tissue enhancement compared to two existing preclinical CT contrast agents, Mvivo-Au, and Fenestra-HDVC. Healthy nude mice were administered one of the three contrast agents. CT imaging was performed before and at 5 minutes, 1 hour, 4 hours, 24 hours, 48 hours, 96 hours, and 7 days post-injection. Tissue intensity and the enhancement ratio relative to pre-injection levels were quantified for each contrast agent at each time point. VivoVist demonstrated significantly higher blood enhancement compared to Mvivo-Au and Fenestra-HDVC at 5 minutes and 1 hour post-injection. However, the enhancement at 4 hours and later time points was inferior to that of Mvivo-Au. VivoVist exhibited the fastest blood clearance among the three contrast agents, with a blood half-life of 3.1 hours and was largely cleared from the blood by 24 hours post-injection. In CT imaging after 24 hours post-injection, VivoVist showed the highest liver enhancement, which remained high over the 7-day imaging period. Biodistribution assessment showed that the splenic uptake of VivoVist was extremely high. Histological examination of the tissues identified abundant contrast agent accumulation in the liver and spleen. No overt pathological changes were observed in either organ one month after the injection of VivoVist. Overall, the evaluation confirmed that VivoVist is an effective CT contrast agent for vascular and liver imaging with low toxicity. However, its relatively short blood half-life limits its use as a vascular contrast agent for a prolonged period.

PLoS ONEVol. 20(10)
University of North Carolina at Chapel Hill (US), Imaging Center (US)
Openalex Percentile: Top 69%
Ultrasound and Hyperthermia Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.