Shear Performance of Different Interstory Connections in Fabricated Light‐Steel Walls

The interstory connections of light‐steel walls, as a critical part for force transmission in light‐steel structures, directly affects the lateral deformation of the wall and the effective transfer of interstory shear force. Little study has been conducted on the interstory connections of light‐steel walls previously. Thus, 18 specimens were experimentally investigated to study the shear performance of interstory connections in light‐steel walls. The effects of stiffener length, screw number, and web connection on the shear performance of the interstory connections were examined. The influence of various interstory connection configurations on the failure modes, hysteresis curves, skeleton curves, stiffness curves, and shear bearing capacity of the specimens was analyzed. The results showed that the joists buckled earlier when only hold‐down bolts were provided, and the shear performance of the specimens did not significantly improve. When stiffeners were provided, the shear capacity of the specimens increased, while the stiffness showed no significant variation. Additionally, changing the stiffener length had little effect on the specimen’s stiffness, and the number of screws connecting the stiffeners to the joists had no significant effect on the stiffness. For specimens with stiffeners and rigid blockings, the force performance improved considerably. Additionally, the shear capacity and stiffness of the specimens with rigid blockings were increased by 1.3 and 2.2 times, respectively. The number of screws connecting the rigid blockings to angles and stiffeners had no significant effect on the stiffness of the interstory connections in light‐steel walls. Based on the test results, the formula for calculating the shear stiffness of light‐steel structure interstory connections was established. The calculation results coincide well with the test results.

Authors

Institutions

Publication Details

Journal
Advances in Civil Engineering
Published
2025-01-01
DOI
https://doi.org/10.1155/adce/6638161
Primary Topic
Structural Load-Bearing Analysis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Shear Performance of Different Interstory Connections in Fabricated Light‐Steel Walls

Sha Liu, J Wang, Rui Wei, Guocheng Yang et al.
Advances in Civil Engineering
Structural Load-Bearing Analysis
article

Shear Performance of Different Interstory Connections in Fabricated Light‐Steel Walls

Sha Liu, J Wang, Rui Wei, Guocheng Yang, Yu Shi, Zhijun Wang, Yan Zou
article en

Abstract

The interstory connections of light‐steel walls, as a critical part for force transmission in light‐steel structures, directly affects the lateral deformation of the wall and the effective transfer of interstory shear force. Little study has been conducted on the interstory connections of light‐steel walls previously. Thus, 18 specimens were experimentally investigated to study the shear performance of interstory connections in light‐steel walls. The effects of stiffener length, screw number, and web connection on the shear performance of the interstory connections were examined. The influence of various interstory connection configurations on the failure modes, hysteresis curves, skeleton curves, stiffness curves, and shear bearing capacity of the specimens was analyzed. The results showed that the joists buckled earlier when only hold‐down bolts were provided, and the shear performance of the specimens did not significantly improve. When stiffeners were provided, the shear capacity of the specimens increased, while the stiffness showed no significant variation. Additionally, changing the stiffener length had little effect on the specimen’s stiffness, and the number of screws connecting the stiffeners to the joists had no significant effect on the stiffness. For specimens with stiffeners and rigid blockings, the force performance improved considerably. Additionally, the shear capacity and stiffness of the specimens with rigid blockings were increased by 1.3 and 2.2 times, respectively. The number of screws connecting the rigid blockings to angles and stiffeners had no significant effect on the stiffness of the interstory connections in light‐steel walls. Based on the test results, the formula for calculating the shear stiffness of light‐steel structure interstory connections was established. The calculation results coincide well with the test results.

Advances in Civil EngineeringVol. 2025(1)
Chongqing University (CN), Ningxia University (CN), Shaanxi Railway Institute (CN), Chongqing University of Technology (CN)
Natural Science Foundation of Ningxia Province, Education Department of Shaanxi Province
Openalex Percentile: Top 67%
Structural Load-Bearing Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.