Reducing the depth data fluctuation error of the binocular imaging system based on the trapezoidal body calibration diagram

In binocular vision systems used in industrial settings, accurate calibration of intrinsic and extrinsic parameters is a prerequisite for ensuring the accuracy of subsequent three-dimensional positioning and dimensional measurement. However, traditional multi-image checkerboard calibration methods rely on a large number of shooting angles. The large cumulative error between images and low calibration accuracy significantly increase the data fluctuation error of the binocular ranging system, making it difficult to meet the "one-time calibration, long-term stability" requirement in industrial scenarios. To address the large error fluctuation in the ranging of small targets at medium and long distances, this study proposes a calibration method based on a single trapezoidal calibration plate. By consolidating the coordinates of all corner points in a unified coordinate system, camera parameters can be measured in a single shot, avoiding calibration failures caused by target occlusion and other issues, and significantly reducing reprojection error and depth data fluctuation. Experimental results show that this method reduces the average reprojection error to 0.31 pixels, approximately 10% lower than the classic Zhang Z. Y. method. Finally, the method is applied to a typical industrial case study: safe distance detection of 110 kV high-voltage cables. The corresponding binocular ranging system improved the standard deviation (SD) and mean square error (MSE) of depth data by 6.90% and 7.47%, respectively, at a working distance of 1.5 m, which verified its reliability and engineering practicality under industrial scenario conditions.

Authors

Publication Details

Journal
Applied Optics
Published
2025-10-31
DOI
https://doi.org/10.1364/ao.575774
Primary Topic
Optical measurement and interference techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reducing the depth data fluctuation error of the binocular imaging system based on the trapezoidal body calibration diagram

Weiyan Liao, Peijie Liu, Guoliang Liu, Jie Qiao et al.
Applied Optics
Optical measurement and interference techniques
article

Reducing the depth data fluctuation error of the binocular imaging system based on the trapezoidal body calibration diagram

Weiyan Liao, Peijie Liu, Guoliang Liu, Jie Qiao, Hao Huang, Yunping Zhong
article en

Abstract

In binocular vision systems used in industrial settings, accurate calibration of intrinsic and extrinsic parameters is a prerequisite for ensuring the accuracy of subsequent three-dimensional positioning and dimensional measurement. However, traditional multi-image checkerboard calibration methods rely on a large number of shooting angles. The large cumulative error between images and low calibration accuracy significantly increase the data fluctuation error of the binocular ranging system, making it difficult to meet the "one-time calibration, long-term stability" requirement in industrial scenarios. To address the large error fluctuation in the ranging of small targets at medium and long distances, this study proposes a calibration method based on a single trapezoidal calibration plate. By consolidating the coordinates of all corner points in a unified coordinate system, camera parameters can be measured in a single shot, avoiding calibration failures caused by target occlusion and other issues, and significantly reducing reprojection error and depth data fluctuation. Experimental results show that this method reduces the average reprojection error to 0.31 pixels, approximately 10% lower than the classic Zhang Z. Y. method. Finally, the method is applied to a typical industrial case study: safe distance detection of 110 kV high-voltage cables. The corresponding binocular ranging system improved the standard deviation (SD) and mean square error (MSE) of depth data by 6.90% and 7.47%, respectively, at a working distance of 1.5 m, which verified its reliability and engineering practicality under industrial scenario conditions.

Applied OpticsVol. 64(35)
Openalex Percentile: Top 68%
Optical measurement and interference techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.