Optimizing the Eden-Hybinette Procedure With 3D-Printed Patient-Specific Instrumentation: A Technical Note

The Eden-Hybinette procedure using an iliac crest bone graft is indicated in cases of recurrent anterior shoulder instability with major glenoid bone loss (>40%), coracoid dysplasia, or failure of Latarjet or Bristow-Latarjet procedures. We describe an open Eden-Hybinette technique supported by a 3D-printed patient-specific cutting guide for iliac crest graft harvesting, combined with a dedicated positioning device (HyLa, Hybrid Latarjet, Newclip Technics®). Preoperative planning based on CT scans allows precise assessment of glenoid bone loss, calculation of graft dimensions, and determination of optimal screw length and orientation. The patient-specific guide enables reproducible tricortical graft harvesting, while the HyLa device provides intraoperative control of graft positioning, avoiding graft overhang or medialization. The technique can be performed either open or arthroscopically. The use of patient-specific instrumentation allowed accurate graft sizing and placement, with postoperative imaging confirming graft congruency and fixation stability. Patients resumed physical activity within six months without recurrence of instability or donor-site morbidity. This technical note highlights the potential advantages of combining 3D-printed patient-specific guides with dedicated instrumentation for the Eden-Hybinette procedure. Anticipating graft size, shape, and screw trajectory may improve accuracy, reproducibility, and safety in revision shoulder stabilization. Further clinical studies are required to validate outcomes compared with conventional techniques.

Authors

Institutions

Publication Details

Journal
Cureus
Published
2025-10-31
DOI
https://doi.org/10.7759/cureus.95817
Primary Topic
Shoulder Injury and Treatment
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimizing the Eden-Hybinette Procedure With 3D-Printed Patient-Specific Instrumentation: A Technical Note

Bernard de Geofroy, Damien Lami, Camille Choufani, Jean-Charles Grillo et al.
Cureus
Shoulder Injury and Treatment
article

Optimizing the Eden-Hybinette Procedure With 3D-Printed Patient-Specific Instrumentation: A Technical Note

Bernard de Geofroy, Damien Lami, Camille Choufani, Jean-Charles Grillo, Anne-Sophie Lamort
article en

Abstract

The Eden-Hybinette procedure using an iliac crest bone graft is indicated in cases of recurrent anterior shoulder instability with major glenoid bone loss (>40%), coracoid dysplasia, or failure of Latarjet or Bristow-Latarjet procedures. We describe an open Eden-Hybinette technique supported by a 3D-printed patient-specific cutting guide for iliac crest graft harvesting, combined with a dedicated positioning device (HyLa, Hybrid Latarjet, Newclip Technics®). Preoperative planning based on CT scans allows precise assessment of glenoid bone loss, calculation of graft dimensions, and determination of optimal screw length and orientation. The patient-specific guide enables reproducible tricortical graft harvesting, while the HyLa device provides intraoperative control of graft positioning, avoiding graft overhang or medialization. The technique can be performed either open or arthroscopically. The use of patient-specific instrumentation allowed accurate graft sizing and placement, with postoperative imaging confirming graft congruency and fixation stability. Patients resumed physical activity within six months without recurrence of instability or donor-site morbidity. This technical note highlights the potential advantages of combining 3D-printed patient-specific guides with dedicated instrumentation for the Eden-Hybinette procedure. Anticipating graft size, shape, and screw trajectory may improve accuracy, reproducibility, and safety in revision shoulder stabilization. Further clinical studies are required to validate outcomes compared with conventional techniques.

CureusVol. 17(10)
Hôpital Laveran (FR), Institut des Sciences du Mouvement Etienne-Jules Marey (FR), Hôpital d'Instruction des Armées Sainte-Anne (FR), Centre Hospitalier Intercommunal Toulon-La Seyne-sur-Mer (FR), TechnipFMC (Germany) (DE)
Openalex Percentile: Top 50%
Shoulder Injury and Treatment
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.