Comparison of electrical conductivity and freezing point methods for urine osmolality measurement and the influence of urinary biochemical parameters

Abstract Objectives To evaluate the analytical performance of the Sysmex UF-5000 (electrical conductivity) and OSMOMAT 3000 basic (freezing point) devices for urine osmolality measurement and to investigate the influence of urinary biochemical parameters on the trueness of conductivity-based measurements. Methods A total of 210 urine samples were collected from outpatients and analyzed for osmolality using both devices. Urinary concentrations of creatinine, urea, glucose, calcium, potassium, sodium, chloride, total protein, and microalbumin were measured. Precision, trueness, method comparison, and the impact of biochemical parameters were assessed according to CLSI EP05-A3 and EP09-A3 guidelines. Statistical analyses included Spearman’s correlation, Passing–Bablok regression, Bland–Altman plots, and multiple regression analyses to identify predictors of osmolality. Results Both methods demonstrated high repeatability, with total %CV values below 14.2 %. Trueness (%bias) was 7.5 % for Sysmex UF-5000 and 7.1 % for OSMOMAT 3000. No significant difference was observed between median osmolality values (563.5 vs. 541 mOsm/kg, p=0.348). Correlation between devices was strong (Spearman’s rho (ρ)=0.93, p<0.01) and regression analyses indicated that sodium, potassium, calcium, and creatinine significantly influenced osmolality results for both devices. Glucose, urea, and microalbumin had negligible effects on electrical conductivity-based measurements. Conclusions Electrical conductivity may serve as a practical approach for estimating urine osmolality in comparison with the freezing point method, while ionic composition and pH-dependent charged species can still influence particular samples.

Authors

Institutions

Publication Details

Journal
Journal of Laboratory Medicine
Published
2025-10-31
DOI
https://doi.org/10.1515/labmed-2025-0233
Primary Topic
Kidney Stones and Urolithiasis Treatments
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparison of electrical conductivity and freezing point methods for urine osmolality measurement and the influence of urinary biochemical parameters

Mehmet Emre Erol, Murat Alışık, Kübranur Ünal, Mehmet Alp Sert
Journal of Laboratory Medicine
Kidney Stones and Urolithiasis Treatments
article

Comparison of electrical conductivity and freezing point methods for urine osmolality measurement and the influence of urinary biochemical parameters

Mehmet Emre Erol, Murat Alışık, Kübranur Ünal, Mehmet Alp Sert
article en

Abstract

Abstract Objectives To evaluate the analytical performance of the Sysmex UF-5000 (electrical conductivity) and OSMOMAT 3000 basic (freezing point) devices for urine osmolality measurement and to investigate the influence of urinary biochemical parameters on the trueness of conductivity-based measurements. Methods A total of 210 urine samples were collected from outpatients and analyzed for osmolality using both devices. Urinary concentrations of creatinine, urea, glucose, calcium, potassium, sodium, chloride, total protein, and microalbumin were measured. Precision, trueness, method comparison, and the impact of biochemical parameters were assessed according to CLSI EP05-A3 and EP09-A3 guidelines. Statistical analyses included Spearman’s correlation, Passing–Bablok regression, Bland–Altman plots, and multiple regression analyses to identify predictors of osmolality. Results Both methods demonstrated high repeatability, with total %CV values below 14.2 %. Trueness (%bias) was 7.5 % for Sysmex UF-5000 and 7.1 % for OSMOMAT 3000. No significant difference was observed between median osmolality values (563.5 vs. 541 mOsm/kg, p=0.348). Correlation between devices was strong (Spearman’s rho (ρ)=0.93, p<0.01) and regression analyses indicated that sodium, potassium, calcium, and creatinine significantly influenced osmolality results for both devices. Glucose, urea, and microalbumin had negligible effects on electrical conductivity-based measurements. Conclusions Electrical conductivity may serve as a practical approach for estimating urine osmolality in comparison with the freezing point method, while ionic composition and pH-dependent charged species can still influence particular samples.

Journal of Laboratory MedicineVol. 50(1)
Kütahya Dumlupınar Üniversitesi (TR), Bolu Abant İzzet Baysal University (TR), Gazi University (TR)
Gazi Üniversitesi
Openalex Percentile: Top 54%
Kidney Stones and Urolithiasis Treatments
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.