Towards accurate penetration depth estimation in near-infrared spectroscopy: a quantitative analysis of source-detector distance dependence in porcine kidney models

Understanding the depth of penetration of near-infrared (NIR) light in biological tissue is critical for enhancing clinical applications of near-infrared spectroscopy (NIRS). The current knowledge of NIRS penetration depth primarily stems from mathematical models, numerical simulations, and phantom studies, with a notable knowledge gap derived from real animal models. By sequentially obstructing light from traversing in a porcine kidney tissue model, we derived the depth distribution of NIR light experimentally and better characterized its dependence on the distance between the light source and photodetector. We collected four replicates of data from six different source-detector distances (SDSs) and found that both the maximum and mean depths of penetration of NIRS increase with the SDS. Linear relationships can be derived between the SDS and the maximum depth, and the square root of the SDS and the mean depth.

Authors

Institutions

Publication Details

Journal
Biomedical Optics Express
Published
2025-10-31
DOI
https://doi.org/10.1364/boe.572790
Primary Topic
Optical Imaging and Spectroscopy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Towards accurate penetration depth estimation in near-infrared spectroscopy: a quantitative analysis of source-detector distance dependence in porcine kidney models

Babak Shadgan, Arshdeep Khurana, Alireza Khodavandi, Iman Amani Tehrani
Biomedical Optics Express
Optical Imaging and Spectroscopy Techniques
article

Towards accurate penetration depth estimation in near-infrared spectroscopy: a quantitative analysis of source-detector distance dependence in porcine kidney models

Babak Shadgan, Arshdeep Khurana, Alireza Khodavandi, Iman Amani Tehrani
article en

Abstract

Understanding the depth of penetration of near-infrared (NIR) light in biological tissue is critical for enhancing clinical applications of near-infrared spectroscopy (NIRS). The current knowledge of NIRS penetration depth primarily stems from mathematical models, numerical simulations, and phantom studies, with a notable knowledge gap derived from real animal models. By sequentially obstructing light from traversing in a porcine kidney tissue model, we derived the depth distribution of NIR light experimentally and better characterized its dependence on the distance between the light source and photodetector. We collected four replicates of data from six different source-detector distances (SDSs) and found that both the maximum and mean depths of penetration of NIRS increase with the SDS. Linear relationships can be derived between the SDS and the maximum depth, and the square root of the SDS and the mean depth.

Biomedical Optics ExpressVol. 16(12)
University of British Columbia (CA), International Collaboration On Repair Discoveries (CA)
Openalex Percentile: Top 54%
Optical Imaging and Spectroscopy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Towards accurate penetration depth estimation in near-infrared spectroscopy: a quantitative analysis of source-detector distance dependence in porcine kidney models — Babak Shadgan, Arshdeep Khurana, et al. · Biomedical Optics Express (2025) | TGRS Research Map | TGRS