Changes in anterior segment parameters after neodymium-doped yttrium-aluminum-garnet laser capsulotomy: A prospective study

ObjectiveThis prospective study aimed to evaluate anterior segment parameters after neodymium-doped yttrium-aluminum-garnet laser posterior capsulotomy.MethodsThe central corneal thickness, anterior chamber depth, lens vault, and pupil diameter measurements were taken using the novel anterior segment swept-source optical coherence tomography system. The tilt of the intraocular lens was measured with the Optical Path Difference Scan III. The examinations were performed preoperatively and repeated at postoperative 30 min, 1 week, and 1 month. The patients were divided into two groups according to the type of lens used: C-loop-type (n = 18) and plate-type (n = 18) intraocular lens.ResultsThe mean central corneal thickness (<i>p </i><<i> </i>0.001), anterior chamber depth (<i>p </i><<i> </i>0.001), and lens vault (<i>p </i>=<i> </i>0.005) were increased significantly at 30 min and then returned to baseline values at 1 week and 1 month after the capsulotomy. Furthermore, the mean increase in the degree of anterior chamber depth and lens vault in the plate-type intraocular lens group was more than that in the C-loop-type intraocular lens group at postoperative 30 min; however, these increases were not significantly different (<i>p </i>><i> </i>0.05). The mean tilt of the intraocular lens values did not change significantly after capsulotomy in both groups.ConclusionNeodymium-doped yttrium-aluminum-garnet capsulotomy causes a temporary increase in the central corneal thickness, anterior chamber depth, and lens vault; however, it does not significantly alter the tilt of the intraocular lens.

Authors

Institutions

Publication Details

Journal
Journal of International Medical Research
Published
2025-10-01
DOI
https://doi.org/10.1177/03000605251389806
Primary Topic
Intraocular Surgery and Lenses
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Changes in anterior segment parameters after neodymium-doped yttrium-aluminum-garnet laser capsulotomy: A prospective study

Bei Zhang, Yu-Kun Mao, Haiyang Yu
Journal of International Medical Research
Intraocular Surgery and Lenses
article

Changes in anterior segment parameters after neodymium-doped yttrium-aluminum-garnet laser capsulotomy: A prospective study

Bei Zhang, Yu-Kun Mao, Haiyang Yu
article en

Abstract

ObjectiveThis prospective study aimed to evaluate anterior segment parameters after neodymium-doped yttrium-aluminum-garnet laser posterior capsulotomy.MethodsThe central corneal thickness, anterior chamber depth, lens vault, and pupil diameter measurements were taken using the novel anterior segment swept-source optical coherence tomography system. The tilt of the intraocular lens was measured with the Optical Path Difference Scan III. The examinations were performed preoperatively and repeated at postoperative 30 min, 1 week, and 1 month. The patients were divided into two groups according to the type of lens used: C-loop-type (n = 18) and plate-type (n = 18) intraocular lens.ResultsThe mean central corneal thickness (<i>p </i><<i> </i>0.001), anterior chamber depth (<i>p </i><<i> </i>0.001), and lens vault (<i>p </i>=<i> </i>0.005) were increased significantly at 30 min and then returned to baseline values at 1 week and 1 month after the capsulotomy. Furthermore, the mean increase in the degree of anterior chamber depth and lens vault in the plate-type intraocular lens group was more than that in the C-loop-type intraocular lens group at postoperative 30 min; however, these increases were not significantly different (<i>p </i>><i> </i>0.05). The mean tilt of the intraocular lens values did not change significantly after capsulotomy in both groups.ConclusionNeodymium-doped yttrium-aluminum-garnet capsulotomy causes a temporary increase in the central corneal thickness, anterior chamber depth, and lens vault; however, it does not significantly alter the tilt of the intraocular lens.

Journal of International Medical ResearchVol. 53(10)
Sir Run Run Shaw Hospital (CN)
Openalex Percentile: Top 55%
Intraocular Surgery and Lenses
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.