A Comprehensive Computational Workflow for Patient-Specific 3D Reconstruction and Quantitative Analysis of Acetabular Revision Defects

Quantitative analysis of acetabular bone loss in hip revision surgery remain limited. This hinders evidence-based implant selection and the development of standardised defect models. We present a computational workflow to reconstruct patient-specific revision cases as three-dimensional (3D) defect volume models to derive intersections and multi-sphere models. A total of 47 acetabular revision cases (Paprosky IIA–IIIB) were processed retrospectively. The acetabular defect surface mesh was isolated using curvature-guided manual refinement (mean boundary error: 2.62 ± 1.69 mm), followed by distortion-free scaling and weighted alignment to a statistical shape model (SSM) of the pelvis. Two strategies were implemented to define the defect volumes: a fast Alpha Method and a high-fidelity Hybrid Model, which supplements the defect model with interior points of the reference pelvis. Threshold-based intersections, spatial defect distribution, and multi-sphere approximations (up to 10 spheres) were generated and benchmarked. The Hybrid Models preserved 77.26 % ± 21.55 % of the original acetabular defect vertices (alpha radius 6.23 ± 4.55), compared to 34.04 % ± 20.26 % for the Alpha Method (alpha radius 32.53 ± 9.97). The intersection analyses revealed a relevant, continuous acetabular margin, which Alpha Method failed to detect. The representative multi-sphere defect models achieved a mean surface error of less than 5 mm. This workflow creates representative 3D volume models of acetabular defects and compact multi-sphere models using standard computed tomography (CT) data. It provides a reproducible, quantitative framework for the objective classification and analysis of defects. It can also support implant planning and provide a standardised defect model for use in experimental or finite element studies.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3626705
Primary Topic
Orthopaedic implants and arthroplasty
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Comprehensive Computational Workflow for Patient-Specific 3D Reconstruction and Quantitative Analysis of Acetabular Revision Defects

Maximilian Fischer, Benjamin Schloßmacher, Christian Fritz, Rüdiger von Eisenhart‐Rothe et al.
IEEE Access
Orthopaedic implants and arthroplasty
article

A Comprehensive Computational Workflow for Patient-Specific 3D Reconstruction and Quantitative Analysis of Acetabular Revision Defects

Maximilian Fischer, Benjamin Schloßmacher, Christian Fritz, Rüdiger von Eisenhart‐Rothe, Rainer Burgkart, Jan J. Lang, Igor Lazic, Carina M. Micheler, Florian Hinterwimmer, H. Wolf
article en

Abstract

Quantitative analysis of acetabular bone loss in hip revision surgery remain limited. This hinders evidence-based implant selection and the development of standardised defect models. We present a computational workflow to reconstruct patient-specific revision cases as three-dimensional (3D) defect volume models to derive intersections and multi-sphere models. A total of 47 acetabular revision cases (Paprosky IIA–IIIB) were processed retrospectively. The acetabular defect surface mesh was isolated using curvature-guided manual refinement (mean boundary error: 2.62 ± 1.69 mm), followed by distortion-free scaling and weighted alignment to a statistical shape model (SSM) of the pelvis. Two strategies were implemented to define the defect volumes: a fast Alpha Method and a high-fidelity Hybrid Model, which supplements the defect model with interior points of the reference pelvis. Threshold-based intersections, spatial defect distribution, and multi-sphere approximations (up to 10 spheres) were generated and benchmarked. The Hybrid Models preserved 77.26 % ± 21.55 % of the original acetabular defect vertices (alpha radius 6.23 ± 4.55), compared to 34.04 % ± 20.26 % for the Alpha Method (alpha radius 32.53 ± 9.97). The intersection analyses revealed a relevant, continuous acetabular margin, which Alpha Method failed to detect. The representative multi-sphere defect models achieved a mean surface error of less than 5 mm. This workflow creates representative 3D volume models of acetabular defects and compact multi-sphere models using standard computed tomography (CT) data. It provides a reproducible, quantitative framework for the objective classification and analysis of defects. It can also support implant planning and provide a standardised defect model for use in experimental or finite element studies.

IEEE AccessVol. 13
Fraunhofer Institute for Machine Tools and Forming Technology (DE), IQ Solutions (US), Technical University of Munich (DE)
Openalex Percentile: Top 51%
Orthopaedic implants and arthroplasty
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.