Low Complexity Point Tracking of the Myocardium in 2D Echocardiography

Deep learning methods for point tracking are applicable in 2D echocardiography, but do not yet take advantage of domain specifics that enable extremely fast and efficient configurations. We developed MyoTracker, a low-complexity architecture (0.3M parameters) for point tracking in echocardiography. It builds on the CoTracker2 architecture by simplifying its components and extending the temporal context to provide point predictions for the entire sequence in a single step. We applied MyoTracker to the right ventricular (RV) myocardium in RV-focused recordings and compared the results with those of CoTracker2 and EchoTracker, another specialized point tracking architecture for echocardiography. MyoTracker achieved the lowest average point trajectory error at 2.00±0.53 mm. Calculating RV Free Wall Strain (RV FWS) using MyoTracker’s point predictions resulted in a -0.3% bias with 95% limits of agreement from -6.1% to 5.4% compared to reference values from commercial software. This range falls within the interobserver variability reported in previous studies. The limits of agreement were wider for both CoTracker2 and EchoTracker, worse than the interobserver variability. At inference, MyoTracker used 67% less GPU memory than CoTracker2 and 84% less than EchoTracker on large sequences (100 frames). MyoTracker was 74 times faster during inference than CoTracker2 and 11 times faster than EchoTracker with our setup. Maintaining the entire sequence in the temporal context was the greatest contributor to MyoTracker’s accuracy. Slight additional gains can be made by re-enabling iterative refinement, at the cost of longer processing time. MyoTracker source code: https://github.com/artemcher/myotracker.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3627527
Citations
1
Primary Topic
Cardiovascular Function and Risk Factors
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low Complexity Point Tracking of the Myocardium in 2D Echocardiography

John Nyberg, Svein Arne Aase, Andreas Østvik, Håvard Dalen et al.
1 citations
IEEE Access
Cardiovascular Function and Risk Factors
1.39
article

Low Complexity Point Tracking of the Myocardium in 2D Echocardiography

John Nyberg, Svein Arne Aase, Andreas Østvik, Håvard Dalen, Lasse Løvstakken, V Holmstrom, Bjørnar Grenne, Md Abulkalam Azad, Artem Chernyshov
article en
1 citations

Abstract

Deep learning methods for point tracking are applicable in 2D echocardiography, but do not yet take advantage of domain specifics that enable extremely fast and efficient configurations. We developed MyoTracker, a low-complexity architecture (0.3M parameters) for point tracking in echocardiography. It builds on the CoTracker2 architecture by simplifying its components and extending the temporal context to provide point predictions for the entire sequence in a single step. We applied MyoTracker to the right ventricular (RV) myocardium in RV-focused recordings and compared the results with those of CoTracker2 and EchoTracker, another specialized point tracking architecture for echocardiography. MyoTracker achieved the lowest average point trajectory error at 2.00±0.53 mm. Calculating RV Free Wall Strain (RV FWS) using MyoTracker’s point predictions resulted in a -0.3% bias with 95% limits of agreement from -6.1% to 5.4% compared to reference values from commercial software. This range falls within the interobserver variability reported in previous studies. The limits of agreement were wider for both CoTracker2 and EchoTracker, worse than the interobserver variability. At inference, MyoTracker used 67% less GPU memory than CoTracker2 and 84% less than EchoTracker on large sequences (100 frames). MyoTracker was 74 times faster during inference than CoTracker2 and 11 times faster than EchoTracker with our setup. Maintaining the entire sequence in the temporal context was the greatest contributor to MyoTracker’s accuracy. Slight additional gains can be made by re-enabling iterative refinement, at the cost of longer processing time. MyoTracker source code: https://github.com/artemcher/myotracker.

IEEE AccessVol. 13
Norwegian University of Science and Technology (NO)
Openalex Percentile: Top 14%
Cardiovascular Function and Risk Factors
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.