Handheld ultrasound assessment of the inferior vena cava and nursing care in an older adult patient with suspected heart failure: a case study

Periodic inferior vena cava assessments can help to detect signs of congestion. This article presents a case involving an 84-year-old patient receiving home care. The aim was to evaluate whether the inferior vena cava diameters had diurnal variation, as well as whether inferior vena cava-based assessment of congestion is useful for nursing care. Using a handheld ultrasound device, the inferior vena cava diameter was measured five times over the course of a day to evaluate diurnal variation. The maximum and minimum inferior vena cava diameters were 2.2–2.3 and 0.9–1.0 cm, respectively, with a respiratory variation rate of 54.5–60.9%. The coefficients of variation were 2.0%, 4.0%, and 4.0%, respectively. The estimated right atrial pressure was 8 mmHg, suggesting slight congestion. No significant diurnal variation was observed. These findings guided nursing care by ensuring more focus on congestion management, including enhanced symptom observation and multidisciplinary collaboration.

Authors

Institutions

Publication Details

Journal
British Journal of Cardiac Nursing
Published
2025-10-02
DOI
https://doi.org/10.12968/bjca.2025.0017
Primary Topic
Hemodynamic Monitoring and Therapy
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Handheld ultrasound assessment of the inferior vena cava and nursing care in an older adult patient with suspected heart failure: a case study

Aya Kitamura, Fumiya Oohashi, Yoko Uchida
British Journal of Cardiac Nursing
Hemodynamic Monitoring and Therapy
article

Handheld ultrasound assessment of the inferior vena cava and nursing care in an older adult patient with suspected heart failure: a case study

Aya Kitamura, Fumiya Oohashi, Yoko Uchida
article en

Abstract

Periodic inferior vena cava assessments can help to detect signs of congestion. This article presents a case involving an 84-year-old patient receiving home care. The aim was to evaluate whether the inferior vena cava diameters had diurnal variation, as well as whether inferior vena cava-based assessment of congestion is useful for nursing care. Using a handheld ultrasound device, the inferior vena cava diameter was measured five times over the course of a day to evaluate diurnal variation. The maximum and minimum inferior vena cava diameters were 2.2–2.3 and 0.9–1.0 cm, respectively, with a respiratory variation rate of 54.5–60.9%. The coefficients of variation were 2.0%, 4.0%, and 4.0%, respectively. The estimated right atrial pressure was 8 mmHg, suggesting slight congestion. No significant diurnal variation was observed. These findings guided nursing care by ensuring more focus on congestion management, including enhanced symptom observation and multidisciplinary collaboration.

British Journal of Cardiac NursingVol. 20(10)
Gunma University (JP), Ishikawa Prefectural Nursing University (JP)
Openalex Percentile: Top 51%
Hemodynamic Monitoring and Therapy
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies