Novel rapid screening device for carotid artery stenosis using video motion analysis: From concept to product

Stroke is the leading cause of death worldwide. Carotid artery stenosis (CAS) is an early indicator of stroke, as well as a risk factor for vascular diseases. Currently, the preferred choice among non-invasive diagnosis tools for assessing CAS severity is carotid Doppler ultrasound; however, it is impractical for use in screening. In this study, the PulStroke project was initiated in our laboratory to transform the video motion analysis (VMA) developed by the authors into a commercial product using a user-centric design approach, with the goal of completing CAS screening with ease. A user takes a 20-second video clip with the PulStroke device, and with just one simple screen touch, the video clip is recorded and automatically uploaded to a cloud server for the assessment of CAS risk. VMA analyzes the video clip, and a risk report is sent to the user's account in 5 min. This process is achieved with an automated system featuring hardware integration and streamlined operation flow via backend/frontend software architecture. This paper presents the methodology used to advance the technology readiness level from 1 to 6, highlighting the evolution of the device and method, called the PulStroke as a potential brand name, from concept to product. As part of the technology maturity evaluation, the PulStroke was tested on target users, i.e., medical and non-medical professionals, for the user experience and post-screening feedback. Most users found the PulStroke to be fully functional and easy to use, and the satisfaction rate was higher than 88 %. The PulStroke device could be incorporated into future clinical practice to provide the general public with quick and cost-effective CAS screening for the first time.

Authors

Institutions

Publication Details

Journal
Computational and Structural Biotechnology Journal
Published
2025-01-01
DOI
https://doi.org/10.1016/j.csbj.2025.10.055
Primary Topic
Cerebrovascular and Carotid Artery Diseases
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel rapid screening device for carotid artery stenosis using video motion analysis: From concept to product

Pengjie Wang, Ching‐Chang Huang, Hsien‐Li Kao, Hsin-Fang Hsu et al.
Computational and Structural Biotechnology Journal
Cerebrovascular and Carotid Artery Diseases
article

Novel rapid screening device for carotid artery stenosis using video motion analysis: From concept to product

Pengjie Wang, Ching‐Chang Huang, Hsien‐Li Kao, Hsin-Fang Hsu, Li‐Han Lin, K Fan, Yuting Shen, Hao‐Ming Hsiao
article en

Abstract

Stroke is the leading cause of death worldwide. Carotid artery stenosis (CAS) is an early indicator of stroke, as well as a risk factor for vascular diseases. Currently, the preferred choice among non-invasive diagnosis tools for assessing CAS severity is carotid Doppler ultrasound; however, it is impractical for use in screening. In this study, the PulStroke project was initiated in our laboratory to transform the video motion analysis (VMA) developed by the authors into a commercial product using a user-centric design approach, with the goal of completing CAS screening with ease. A user takes a 20-second video clip with the PulStroke device, and with just one simple screen touch, the video clip is recorded and automatically uploaded to a cloud server for the assessment of CAS risk. VMA analyzes the video clip, and a risk report is sent to the user's account in 5 min. This process is achieved with an automated system featuring hardware integration and streamlined operation flow via backend/frontend software architecture. This paper presents the methodology used to advance the technology readiness level from 1 to 6, highlighting the evolution of the device and method, called the PulStroke as a potential brand name, from concept to product. As part of the technology maturity evaluation, the PulStroke was tested on target users, i.e., medical and non-medical professionals, for the user experience and post-screening feedback. Most users found the PulStroke to be fully functional and easy to use, and the satisfaction rate was higher than 88 %. The PulStroke device could be incorporated into future clinical practice to provide the general public with quick and cost-effective CAS screening for the first time.

Computational and Structural Biotechnology JournalVol. 28
National Taiwan University (TW), National Taiwan University Hospital (TW)
National Science and Technology Council
Openalex Percentile: Top 55%
Cerebrovascular and Carotid Artery Diseases
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.