A simple NIR fluorescent probe for detecting pH in actual water samples and cells

In this work, we presented a new probe (named FC) that can respond rapidly to pH. In an acidic setting, the NIR fluorescence of FC was quenched upon protonation of the pyridine moiety. FC was a weakly acidic pH probe that could accurately measure the pH within the range of 4.0 to 6.6. The probe exhibited excellent water solubility and could enable the detection of pH in aqueous systems without the need for the involvement of organic solvents. It achieved pH response through photoinduced electron transfer (PET). The fluorescence sensing mechanism and response mechanism were verified through theoretical calculations and nuclear magnetic titration. Furthermore, the probe was employed to monitor the pH level of actual water samples as well as acidity detection within cells.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay01593f
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A simple NIR fluorescent probe for detecting pH in actual water samples and cells

Qing Mei, Ruizhen Zhang, Feng Li
Analytical Methods
Molecular Sensors and Ion Detection
article

A simple NIR fluorescent probe for detecting pH in actual water samples and cells

Qing Mei, Ruizhen Zhang, Feng Li
article en

Abstract

In this work, we presented a new probe (named FC) that can respond rapidly to pH. In an acidic setting, the NIR fluorescence of FC was quenched upon protonation of the pyridine moiety. FC was a weakly acidic pH probe that could accurately measure the pH within the range of 4.0 to 6.6. The probe exhibited excellent water solubility and could enable the detection of pH in aqueous systems without the need for the involvement of organic solvents. It achieved pH response through photoinduced electron transfer (PET). The fluorescence sensing mechanism and response mechanism were verified through theoretical calculations and nuclear magnetic titration. Furthermore, the probe was employed to monitor the pH level of actual water samples as well as acidity detection within cells.

Analytical MethodsVol. 17(46)
Qilu University of Technology (CN), Shandong University (CN)
Openalex Percentile: Top 71%
Molecular Sensors and Ion Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.