Development and Control Factor Derivation for Recycling Scrubber Effluent for Incinerator Flue Gas Treatment

ABSTRACT This study explores a wastewater reuse method for the wet scrubber system used in incinerator flue gas treatment. Analysis of actual scrubber wastewater revealed particulate matter with a mode size of 62.22 μm, primarily due to activated carbon used for dioxin removal. High concentrations of SO₄ 2− (9607 mg/L) and Cl − (8305 mg/L) were observed, originating from acidic gases such as SOx and HCl neutralized with 33% NaOH, leaving residual Na + at 12 479 mg/L. A disk filter and ion exchange process were introduced to assess wastewater reuse feasibility and optimize operational parameters through lab‐scale tests. Results confirmed that particulate removal via the disk filter and OH − substitution using ion exchange enabled wastewater reuse. Applying this process to a 100‐t/day industrial waste incineration facility is projected to recycle 80% of the scrubber wastewater, reducing annual operating costs by approximately 30.28%, or USD 232 230.

Authors

Institutions

Publication Details

Journal
Water and Environment Journal
Published
2025-10-29
DOI
https://doi.org/10.1111/wej.70023
Primary Topic
Industrial Gas Emission Control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Development and Control Factor Derivation for Recycling Scrubber Effluent for Incinerator Flue Gas Treatment

Eunsil Lee, Yongho Lee, Eun Ju Kim
Water and Environment Journal
Industrial Gas Emission Control
article

Development and Control Factor Derivation for Recycling Scrubber Effluent for Incinerator Flue Gas Treatment

Eunsil Lee, Yongho Lee, Eun Ju Kim
article en

Abstract

ABSTRACT This study explores a wastewater reuse method for the wet scrubber system used in incinerator flue gas treatment. Analysis of actual scrubber wastewater revealed particulate matter with a mode size of 62.22 μm, primarily due to activated carbon used for dioxin removal. High concentrations of SO₄ 2− (9607 mg/L) and Cl − (8305 mg/L) were observed, originating from acidic gases such as SOx and HCl neutralized with 33% NaOH, leaving residual Na + at 12 479 mg/L. A disk filter and ion exchange process were introduced to assess wastewater reuse feasibility and optimize operational parameters through lab‐scale tests. Results confirmed that particulate removal via the disk filter and OH − substitution using ion exchange enabled wastewater reuse. Applying this process to a 100‐t/day industrial waste incineration facility is projected to recycle 80% of the scrubber wastewater, reducing annual operating costs by approximately 30.28%, or USD 232 230.

Water and Environment Journal
Institute for Advanced Engineering (KR)
Openalex Percentile: Top 67%
Industrial Gas Emission Control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.