Innovation of Spectroscopic Approach for Investigation of Lurasidone in Pharmaceutical Formulations and Spiked Human Plasma

A fast and economical flow injection-fluorometric technique has been employed for the estimation of lurasidone (LUR) in pharmaceutical formulations and biological fluids. LUR natively fluoresces due to the presence of the benzothiazole ring in its chemical composition. The assay relies on detecting the intense native fluorescence of LUR at 398 nm after excitation at 316 nm. Phosphate buffer (pH: 4.5, 10 mM): Acetonitrile (30:70 v/v) was used as the carrier solution, and the flow rate was 0.5 mL min<sup>-1</sup>. Based on peak area, the calibration graph was linear throughout the range of 30-800 ng mL<sup>-1</sup> of LUR with a correlation coefficient (r) of 0.9999. The limit of quantitation was 21.7 ng mL<sup>-1</sup>, while the limit of detection was 7.16 ng mL<sup>-1</sup>. The approach was applied to quantify LUR in pharmaceuticals and human plasma. The approach was assessed in accordance with ICH specifications. There were no excipient-related interferences during the application of the analyses.

Authors

Institutions

Publication Details

Journal
Luminescence
Published
2025-10-29
DOI
https://doi.org/10.1002/bio.70339
Primary Topic
Analytical Methods in Pharmaceuticals
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Innovation of Spectroscopic Approach for Investigation of Lurasidone in Pharmaceutical Formulations and Spiked Human Plasma

Sayed M. Derayea, Khalid M. Badr El‐Din, Mohamed Oraby, Hadeer A. Elhamdy
Luminescence
Analytical Methods in Pharmaceuticals
article

Innovation of Spectroscopic Approach for Investigation of Lurasidone in Pharmaceutical Formulations and Spiked Human Plasma

Sayed M. Derayea, Khalid M. Badr El‐Din, Mohamed Oraby, Hadeer A. Elhamdy
article en

Abstract

A fast and economical flow injection-fluorometric technique has been employed for the estimation of lurasidone (LUR) in pharmaceutical formulations and biological fluids. LUR natively fluoresces due to the presence of the benzothiazole ring in its chemical composition. The assay relies on detecting the intense native fluorescence of LUR at 398 nm after excitation at 316 nm. Phosphate buffer (pH: 4.5, 10 mM): Acetonitrile (30:70 v/v) was used as the carrier solution, and the flow rate was 0.5 mL min<sup>-1</sup>. Based on peak area, the calibration graph was linear throughout the range of 30-800 ng mL<sup>-1</sup> of LUR with a correlation coefficient (r) of 0.9999. The limit of quantitation was 21.7 ng mL<sup>-1</sup>, while the limit of detection was 7.16 ng mL<sup>-1</sup>. The approach was applied to quantify LUR in pharmaceuticals and human plasma. The approach was assessed in accordance with ICH specifications. There were no excipient-related interferences during the application of the analyses.

LuminescenceVol. 40(11)
Minia University (EG), Sohag University (EG)
Openalex Percentile: Top 64%
Analytical Methods in Pharmaceuticals
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.