Improving Microspectroscopic Microplastic Data Extrapolation: From Field of View to Full Sample, and from Fragment 2D-Morphology to Mass

Microplastic (MP) analysis via microspectroscopy typically examines only 1–10% of filter substrates due to time constraints, requiring reliable extrapolation methods for quantitative environmental monitoring. Current subsampling strategies suffer from heterogeneous particle dispersion, leading to 50–80% error in MP quantification. Additionally, MP researchers require enhanced environmental MP mass datasets, necessitating reliable conversion algorithms from two-dimensional morphological data to mass estimates. This study introduces an area-based extrapolation technique for organic rich samples that compares the MP-to-generic particle area ratio within a rectangular field of view against total particle area on the entire filter membrane, combined with a simplified fragment morphology-to-mass conversion model (SFMM). First, two Sphagnum moss samples were analyzed using Raman microspectroscopy and critical angle darkfield illumination microscopy. The results demonstrated stable MP concentrations (17% RSD [n = 8]) despite heterogeneous generic particle distribution (31% RSD [n = 8]), with mean particle-area coverage of 2.4% per subsample. Then, twenty EasyMPTM fragment reference materials (10 µm to 1500 µm), of known composite mass, were used to calibrate two different volume (V) expressions, one based on analyzed particle area (A) and minimum Feret diameter (FMin, i.e., width), yielding V = 0.34 × FMin × A. A second more approximate expression based on only the maximum Feret diameter (FMax, i.e., length) yielded V = 0.097 × (FMax)3. These methods enable MP quantification and mass estimation from limited spectroscopic analysis.

Authors

Institutions

Publication Details

Journal
Microplastics
Published
2025-10-28
DOI
https://doi.org/10.3390/microplastics4040080
Primary Topic
Microplastics and Plastic Pollution
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Improving Microspectroscopic Microplastic Data Extrapolation: From Field of View to Full Sample, and from Fragment 2D-Morphology to Mass

Jeroen E. Sonke, Nadiia Yakovenko, Henar Margenat, Oskar Hagelskjær et al.
Microplastics
Microplastics and Plastic Pollution
article

Improving Microspectroscopic Microplastic Data Extrapolation: From Field of View to Full Sample, and from Fragment 2D-Morphology to Mass

Jeroen E. Sonke, Nadiia Yakovenko, Henar Margenat, Oskar Hagelskjær, Gaël Le Roux
article en

Abstract

Microplastic (MP) analysis via microspectroscopy typically examines only 1–10% of filter substrates due to time constraints, requiring reliable extrapolation methods for quantitative environmental monitoring. Current subsampling strategies suffer from heterogeneous particle dispersion, leading to 50–80% error in MP quantification. Additionally, MP researchers require enhanced environmental MP mass datasets, necessitating reliable conversion algorithms from two-dimensional morphological data to mass estimates. This study introduces an area-based extrapolation technique for organic rich samples that compares the MP-to-generic particle area ratio within a rectangular field of view against total particle area on the entire filter membrane, combined with a simplified fragment morphology-to-mass conversion model (SFMM). First, two Sphagnum moss samples were analyzed using Raman microspectroscopy and critical angle darkfield illumination microscopy. The results demonstrated stable MP concentrations (17% RSD [n = 8]) despite heterogeneous generic particle distribution (31% RSD [n = 8]), with mean particle-area coverage of 2.4% per subsample. Then, twenty EasyMPTM fragment reference materials (10 µm to 1500 µm), of known composite mass, were used to calibrate two different volume (V) expressions, one based on analyzed particle area (A) and minimum Feret diameter (FMin, i.e., width), yielding V = 0.34 × FMin × A. A second more approximate expression based on only the maximum Feret diameter (FMax, i.e., length) yielded V = 0.097 × (FMax)3. These methods enable MP quantification and mass estimation from limited spectroscopic analysis.

MicroplasticsVol. 4(4)
Centre National de la Recherche Scientifique (FR), Université Toulouse III - Paul Sabatier (FR), Université Fédérale de Toulouse Midi-Pyrénées (FR), Laboratoire des Interactions Plantes Microbes Environnement (FR), Géosciences Environnement Toulouse (FR), Institut de Recherche pour le Développement (FR)
Labex DRIIHM, Agence Nationale de la Recherche, Centre National de la Recherche Scientifique, Interreg
Openalex Percentile: Top 75%
Microplastics and Plastic Pollution
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.