Validation of 4TP Impedance Bridge Developed at GUM

Impedance methods are gaining importance each year and have recently become an essential tool for diagnosing batteries, capacitors, and fuel cells. In this article we present the results of validating the digital impedance bridge developed by the National Metrology Institute (GUM) in Warsaw, Poland. The comparison involved new impedance standards recently developed by GUM and the Silesian University of Technology (SUT), as well as standards developed by the Swiss National Metrology Institute (METAS). The comparison of the standard resistors and capacitors demonstrated agreement between the measurement results obtained with the Polish and Swiss sampling bridges, with a deviation of 5 µΩ/Ω in the frequency range from 500 Hz to 5 kHz.

Authors

Institutions

Publication Details

Journal
Energies
Published
2025-10-29
DOI
https://doi.org/10.3390/en18215690
Primary Topic
Advanced Electrical Measurement Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Validation of 4TP Impedance Bridge Developed at GUM

Jolanta Jursza, Maciej Koszarny, Adam Ziółek, Krzysztof Musioł et al.
Energies
Advanced Electrical Measurement Techniques
article

Validation of 4TP Impedance Bridge Developed at GUM

Jolanta Jursza, Maciej Koszarny, Adam Ziółek, Krzysztof Musioł, Marian Kampik
article en

Abstract

Impedance methods are gaining importance each year and have recently become an essential tool for diagnosing batteries, capacitors, and fuel cells. In this article we present the results of validating the digital impedance bridge developed by the National Metrology Institute (GUM) in Warsaw, Poland. The comparison involved new impedance standards recently developed by GUM and the Silesian University of Technology (SUT), as well as standards developed by the Swiss National Metrology Institute (METAS). The comparison of the standard resistors and capacitors demonstrated agreement between the measurement results obtained with the Polish and Swiss sampling bridges, with a deviation of 5 µΩ/Ω in the frequency range from 500 Hz to 5 kHz.

EnergiesVol. 18(21)
Silesian University of Technology (PL), Central Office of Measures (PL)
Openalex Percentile: Top 69%
Advanced Electrical Measurement Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.