A Monte Carlo approach to optimising a primary collimator design using EGSnrc

The primary collimator in a clinical linear accelerator (linac) plays a vital role in the radiation shielding of the machine. One objective of the collimation system is to reduce head leakage to less than 0.1 % relative to the dose on the central axis of the main beam. The objective of this study is to investigate the variation in different parameters of a primary collimator to identify a more optimal design through Monte Carlo simulations. Using the Monte-Carlo EGSnrc cavity application, water scoring regions up to 90°, away from the beam axis, were set up to investigate the properties of various tungsten primary collimator sizes and shapes with 6 MeV electrons incident to a target. For a fixed 12 cm length primary collimator, increasing the external radius from 6 cm to 12 cm, decreased side leakage measured at 90° by a factor of 10. Also, increasing the field size opening, increased leakage by a minimum of a factor of 5 at all angles. Extending the fixed 8 cm external radius primary collimator, from 8 cm to 14 cm length, made little difference to the leakage dose, for example, scoring at 45°. This reduction was a factor of 1.5. A conical frustum shape was found to be an optimal shape in terms of the level of shielding provided per unit volume of material compared to a cylinder.

Authors

Institutions

Publication Details

Journal
Physics Open
Published
2025-10-30
DOI
https://doi.org/10.1016/j.physo.2025.100339
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Monte Carlo approach to optimising a primary collimator design using EGSnrc

R F Nutbrown, Tracy Underwood, M Kissick, P. H. Regan et al.
Physics Open
Advanced Radiotherapy Techniques
article

A Monte Carlo approach to optimising a primary collimator design using EGSnrc

R F Nutbrown, Tracy Underwood, M Kissick, P. H. Regan, Anthony Criscuolo, Russell Thomas, D R Shipley
article en

Abstract

The primary collimator in a clinical linear accelerator (linac) plays a vital role in the radiation shielding of the machine. One objective of the collimation system is to reduce head leakage to less than 0.1 % relative to the dose on the central axis of the main beam. The objective of this study is to investigate the variation in different parameters of a primary collimator to identify a more optimal design through Monte Carlo simulations. Using the Monte-Carlo EGSnrc cavity application, water scoring regions up to 90°, away from the beam axis, were set up to investigate the properties of various tungsten primary collimator sizes and shapes with 6 MeV electrons incident to a target. For a fixed 12 cm length primary collimator, increasing the external radius from 6 cm to 12 cm, decreased side leakage measured at 90° by a factor of 10. Also, increasing the field size opening, increased leakage by a minimum of a factor of 5 at all angles. Extending the fixed 8 cm external radius primary collimator, from 8 cm to 14 cm length, made little difference to the leakage dose, for example, scoring at 45°. This reduction was a factor of 1.5. A conical frustum shape was found to be an optimal shape in terms of the level of shielding provided per unit volume of material compared to a cylinder.

Physics OpenVol. 25
National Physical Laboratory (GB), University of Wisconsin–Madison (US), University of Surrey (GB), Crawley Hospital (GB), TÜV SÜD (United Kingdom) (GB), University College London (GB)
Openalex Percentile: Top 58%
Advanced Radiotherapy Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A Monte Carlo approach to optimising a primary collimator design using EGSnrc — R F Nutbrown, Tracy Underwood, et al. · Physics Open (2025) | TGRS Research Map | TGRS