Boosting Electrochemiluminescence of Carbon Nitrides via Molecular Capacitor‐Mediated Spatiotemporal Electron Coordination

Carbon nitride (CN) enables non-toxicity, low cost, high quantum efficiency, and tunable spectrum. Nevertheless, there co-exists a timescale mismatch among kinetic steps of electrochemiluminescence (ECL) and a spatial competition of electrons between radiative recombination and interfacial redox reactions. Herein, a spatiotemporal coordination strategy is reported to enhance Φ<sub>ECL</sub> of CN by molecular capacitor functionalization. Mechanism studies show the capacitor, consisting of N-vacancies and -C≡N terminal groups, dynamically regulates electron capture and accumulation. Interestingly, the spatial confinement of accumulated electrons in molecular capacitors effectively enhances the radiative recombination probability. Meanwhile, the accumulated electrons construct a new pathway for fast electron transport, and the relaxation of the accumulated electrons coordinates the electron transfer in bulk CN and redox reactions at the electrode surface on the µs-ms timescale, establishing temporal coordination across multiple time domains. As a result, the Φ<sub>ECL</sub> of CN increases by up to 100 times, reaching 1480 times that of the standard Ru(bpy)<sub>3</sub>Cl<sub>2</sub>/K<sub>2</sub>S<sub>2</sub>O<sub>8</sub> system. Accordingly, compared to pristine CN, the as-developed ECL sensors using CN with molecular capacitor functionalization demonstrate significantly improved performance in the visual detection of nitrite ions (a typical environmental pollutant), for example, a 3600 fold lower detection limit and a 3-order of magnitude broader detection linear range.

Authors

Institutions

Publication Details

Journal
Advanced Science
Published
2025-10-29
DOI
https://doi.org/10.1002/advs.202506277
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Boosting Electrochemiluminescence of Carbon Nitrides via Molecular Capacitor‐Mediated Spatiotemporal Electron Coordination

Yuanjian Zhang, Kaiqing Wu, Lingling Xiang, Songqin Liu et al.
Advanced Science
Advanced biosensing and bioanalysis techniques
article

Boosting Electrochemiluminescence of Carbon Nitrides via Molecular Capacitor‐Mediated Spatiotemporal Electron Coordination

Yuanjian Zhang, Kaiqing Wu, Lingling Xiang, Songqin Liu, Yuhua Hou, Yanfei Shen, Wang Li, Yu Wang, Yanfeng Fang, Kaiyuan Wang
article en

Abstract

Carbon nitride (CN) enables non-toxicity, low cost, high quantum efficiency, and tunable spectrum. Nevertheless, there co-exists a timescale mismatch among kinetic steps of electrochemiluminescence (ECL) and a spatial competition of electrons between radiative recombination and interfacial redox reactions. Herein, a spatiotemporal coordination strategy is reported to enhance Φ<sub>ECL</sub> of CN by molecular capacitor functionalization. Mechanism studies show the capacitor, consisting of N-vacancies and -C≡N terminal groups, dynamically regulates electron capture and accumulation. Interestingly, the spatial confinement of accumulated electrons in molecular capacitors effectively enhances the radiative recombination probability. Meanwhile, the accumulated electrons construct a new pathway for fast electron transport, and the relaxation of the accumulated electrons coordinates the electron transfer in bulk CN and redox reactions at the electrode surface on the µs-ms timescale, establishing temporal coordination across multiple time domains. As a result, the Φ<sub>ECL</sub> of CN increases by up to 100 times, reaching 1480 times that of the standard Ru(bpy)<sub>3</sub>Cl<sub>2</sub>/K<sub>2</sub>S<sub>2</sub>O<sub>8</sub> system. Accordingly, compared to pristine CN, the as-developed ECL sensors using CN with molecular capacitor functionalization demonstrate significantly improved performance in the visual detection of nitrite ions (a typical environmental pollutant), for example, a 3600 fold lower detection limit and a 3-order of magnitude broader detection linear range.

Advanced ScienceVol. 13(3)
Zhongda Hospital Southeast University (CN), Southeast University (CN)
Strong, National Natural Science Foundation of China, National Key Research and Development Program of China
Openalex Percentile: Top 72%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.