Boosting astrocomb reference performance with a wideband, frequency-stabilized WGM etalon

Astrocombs are highly precise optical reference systems used for astronomical spectrograph calibration, enabling accurate and consistent measurement of stellar absorption line frequencies across a broad spectral range. By comparing a star’s spectrum to the astrocomb spectrum, minute radial velocity shifts indicative of an exoplanet’s presence can be detected. The highest precision and accuracy astrocombs are generated by laser frequency combs. However, in the visible band, frequency comb calibrators have stringent operational lifetime limitations due to degradation of the supercontinuum-generating medium, and are thus typically used to calibrate Fabry–Pérot etalons, which are then used for simultaneous observations with target stars. This work demonstrates a specially designed crystalline whispering-gallery-mode resonator (WGMR) that serves as an astrocomb etalon, featuring a coupling wavelength span of two octaves and a quasi-single-mode family. Several innovations have been incorporated into the system’s compact design to achieve frequency stability, in addition to wide-range wavelength coupling. These include dual-mode thermometric frequency stabilization, in addition to vacuum packaging, effectively minimizing thermal and pressure-induced frequency drift. Long-term frequency stability, measured via a heterodyne RF beat note, exceeds 2×10 −12 , with a projected long-term modal frequency stability of ≲10 −10 (equivalently 3 cm/s in Doppler velocity). This level of stability obviates the need for frequent cross-calibration with a laser reference, as was required with other astrocomb etalons. Overall, the architecture of the WGMR etalon provides a new and powerful capability, beyond what has previously been achieved by microresonator-based etalons, as a compact, ultra-wideband spectral reference for detecting small planets in long-period orbits around nearby stars. It also offers a path forward for a low size, weight, and power (SWaP) spectral reference appropriate for spaceflight.

Authors

Institutions

Publication Details

Journal
Photonics Research
Published
2025-10-29
DOI
https://doi.org/10.1364/prj.577677
Primary Topic
Advanced Fiber Laser Technologies
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Boosting astrocomb reference performance with a wideband, frequency-stabilized WGM etalon

Gautam Vasisht, Lute Maleki, Scott Singer, Charles Beichman et al.
Photonics Research
Advanced Fiber Laser Technologies
article

Boosting astrocomb reference performance with a wideband, frequency-stabilized WGM etalon

Gautam Vasisht, Lute Maleki, Scott Singer, Charles Beichman, Anatoliy A. Savchenkov, Dmitry Strekalov, Mahmood Bagheri, Wei Zhang, Abdelkrim El Amili, Melissa Maldonado, Andrey B. Matsko, Stephanie Leifer, Danny Eliyahu, Yu-Hung Lai, Kayla Kulish
article en

Abstract

Astrocombs are highly precise optical reference systems used for astronomical spectrograph calibration, enabling accurate and consistent measurement of stellar absorption line frequencies across a broad spectral range. By comparing a star’s spectrum to the astrocomb spectrum, minute radial velocity shifts indicative of an exoplanet’s presence can be detected. The highest precision and accuracy astrocombs are generated by laser frequency combs. However, in the visible band, frequency comb calibrators have stringent operational lifetime limitations due to degradation of the supercontinuum-generating medium, and are thus typically used to calibrate Fabry–Pérot etalons, which are then used for simultaneous observations with target stars. This work demonstrates a specially designed crystalline whispering-gallery-mode resonator (WGMR) that serves as an astrocomb etalon, featuring a coupling wavelength span of two octaves and a quasi-single-mode family. Several innovations have been incorporated into the system’s compact design to achieve frequency stability, in addition to wide-range wavelength coupling. These include dual-mode thermometric frequency stabilization, in addition to vacuum packaging, effectively minimizing thermal and pressure-induced frequency drift. Long-term frequency stability, measured via a heterodyne RF beat note, exceeds 2×10 −12 , with a projected long-term modal frequency stability of ≲10 −10 (equivalently 3 cm/s in Doppler velocity). This level of stability obviates the need for frequent cross-calibration with a laser reference, as was required with other astrocomb etalons. Overall, the architecture of the WGMR etalon provides a new and powerful capability, beyond what has previously been achieved by microresonator-based etalons, as a compact, ultra-wideband spectral reference for detecting small planets in long-period orbits around nearby stars. It also offers a path forward for a low size, weight, and power (SWaP) spectral reference appropriate for spaceflight.

Photonics ResearchVol. 14(2)
California Institute of Technology (US), OEwaves (United States) (US)
Openalex Percentile: Top 75%
Advanced Fiber Laser Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.