Dynamic Water Bonding on Clusters Enables Ultrafast Humidity Response and Recovery

Abstract Fast response and recovery are crucial for real‐time human‐body related (HBR) humidity monitoring, which faces a formidable challenge, due to the opposite requirements on interaction intensities of sensing materials with water. Herein, we demonstrate the first cluster‐based humidity sensor with PhQPCu 3 I 3 featuring a semi‐exposed Cu 3 I 3 crown. Compared to ligand encapsulated Cu 4 I 4 clusters, low coordination, short distance and same orientation of iodine atoms in PhQPCu 3 I 3 lead to a rapid and reversible “H 2 O + I…I” reaction. Consequently, besides more than doubled sensitivity of 106 and halved hysteresis error of 3.2% in related humidity range of 11%–97%, PhQPCu 3 I 3 endows its devices with ultrashort response and recovery time of 0.54 and 0.45 s comparable to human reaction time (0.5 s). Owing to its record‐low comprehensive reaction time within 1.0 s, PhQPCu 3 I 3 based sensors were used for real‐time respiratory rate monitoring and non‐contact information input. Our results demonstrate the effectiveness of “dynamic synergistic bonding” in combining rapid water adsorption and desorption and superiority of cluster sensors in real‐time HBR applications.

Authors

Institutions

Publication Details

Journal
Angewandte Chemie
Published
2025-10-29
DOI
https://doi.org/10.1002/ange.202519556
Primary Topic
Gas Sensing Nanomaterials and Sensors
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Dynamic Water Bonding on Clusters Enables Ultrafast Humidity Response and Recovery

Yuanxin Ma, Lei Qu, Baoquan Yang, Hui Xu et al.
Angewandte Chemie
Gas Sensing Nanomaterials and Sensors
article

Dynamic Water Bonding on Clusters Enables Ultrafast Humidity Response and Recovery

Yuanxin Ma, Lei Qu, Baoquan Yang, Hui Xu, Ying Li, Xiaojun Zhang, Cheng‐Bo Han, Yingming Xu, Nan Zhang, Chunbo Duan, Jing Zhang, Chuanyu Guo
article en

Abstract

Abstract Fast response and recovery are crucial for real‐time human‐body related (HBR) humidity monitoring, which faces a formidable challenge, due to the opposite requirements on interaction intensities of sensing materials with water. Herein, we demonstrate the first cluster‐based humidity sensor with PhQPCu 3 I 3 featuring a semi‐exposed Cu 3 I 3 crown. Compared to ligand encapsulated Cu 4 I 4 clusters, low coordination, short distance and same orientation of iodine atoms in PhQPCu 3 I 3 lead to a rapid and reversible “H 2 O + I…I” reaction. Consequently, besides more than doubled sensitivity of 106 and halved hysteresis error of 3.2% in related humidity range of 11%–97%, PhQPCu 3 I 3 endows its devices with ultrashort response and recovery time of 0.54 and 0.45 s comparable to human reaction time (0.5 s). Owing to its record‐low comprehensive reaction time within 1.0 s, PhQPCu 3 I 3 based sensors were used for real‐time respiratory rate monitoring and non‐contact information input. Our results demonstrate the effectiveness of “dynamic synergistic bonding” in combining rapid water adsorption and desorption and superiority of cluster sensors in real‐time HBR applications.

Angewandte ChemieVol. 137(52)
Heilongjiang University (CN)
Openalex Percentile: Top 69%
Gas Sensing Nanomaterials and Sensors
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.