Pulsed scattering events during HEL atmospheric propagation

When employing a High Energy Laser (HEL) in an outdoor environment, a laser safety evaluation has to consider the energy scattered by aerosols during the propagation of the laser. We developed a measurement device SeLMA (ScattEred Laser Measurement Assembly), comprising a set of optical receivers installed on an arc to perform an angularly- and temporally-resolved measurement of this scattered radiation. Measurements with high laser emission intensities revealed powerful pulses in the scattered radiation with the peak power significantly exceeding the average level of the signal. Radiative intensity distribution of the scattered emission was measured in a controlled laboratory environment at various irradiance levels in the laser beam. These results were used for preliminary evaluations of the off-axis ocular hazard distance for a typical HEL operation scenario.

Authors

Institutions

Publication Details

Published
2025-10-29
DOI
https://doi.org/10.1117/12.3069837
Primary Topic
Ocular and Laser Science Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Pulsed scattering events during HEL atmospheric propagation

Adrian Azarian, Max Schiller
Ocular and Laser Science Research
article

Pulsed scattering events during HEL atmospheric propagation

Adrian Azarian, Max Schiller
article en

Abstract

When employing a High Energy Laser (HEL) in an outdoor environment, a laser safety evaluation has to consider the energy scattered by aerosols during the propagation of the laser. We developed a measurement device SeLMA (ScattEred Laser Measurement Assembly), comprising a set of optical receivers installed on an arc to perform an angularly- and temporally-resolved measurement of this scattered radiation. Measurements with high laser emission intensities revealed powerful pulses in the scattered radiation with the peak power significantly exceeding the average level of the signal. Radiative intensity distribution of the scattered emission was measured in a controlled laboratory environment at various irradiance levels in the laser beam. These results were used for preliminary evaluations of the off-axis ocular hazard distance for a typical HEL operation scenario.

Fraunhofer Institute of Optronics, System Technologies and Image Exploitation (DE)
Openalex Percentile: Top 55%
Ocular and Laser Science Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.