Design of Miniaturized Cooled Medium-Wave Infrared Curved Bionic Compound-Eye Optical System

To address the issues of insufficient detector target size and high system complexity in infrared bionic compound-eye systems, this paper designs a miniaturized cooled medium-wave infrared curved bionic compound-eye optical system specifically for large target surface detectors and develops a proof-of-concept prototype for verification. The system comprises three components: (1) a curved multi-aperture array, which consists of 61 sub-apertures with an entrance pupil diameter of 5 mm and a focal length of 10 mm; (2) a cooled planar detector; and (3) a relay imaging system, which adopts secondary imaging technology and achieves the matching between the array and detector with only six infrared lenses. The fill factor is introduced to analyze light energy utilization efficiency, providing a theoretical basis for improving the system’s signal-to-noise ratio and spatial information collection capability; meanwhile, the focal length distribution and pupil matching are analyzed to ensure the system’s optical performance. The system operates within the 3.7–4.8 μm wavelength band, with a total focal length of 3.08 mm, F-number of 2, and field of view reaching 108°. Simulations demonstrate that all sub-aperture imaging channels have MTF values greater than 0.47 at 33.3 lp/mm, with distortion less than 3%. Imaging test results verify that the system possesses excellent imaging performance.

Authors

Institutions

Publication Details

Journal
Photonics
Published
2025-10-29
DOI
https://doi.org/10.3390/photonics12111071
Primary Topic
Advanced optical system design
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Design of Miniaturized Cooled Medium-Wave Infrared Curved Bionic Compound-Eye Optical System

Linhan Li, Kaijun Ma, Nengbin Cai, Sili Gao et al.
Photonics
Advanced optical system design
article

Design of Miniaturized Cooled Medium-Wave Infrared Curved Bionic Compound-Eye Optical System

Linhan Li, Kaijun Ma, Nengbin Cai, Sili Gao, Yang Yu, Fu Wang, Yimin Zhang, Yinghao Chi
article en

Abstract

To address the issues of insufficient detector target size and high system complexity in infrared bionic compound-eye systems, this paper designs a miniaturized cooled medium-wave infrared curved bionic compound-eye optical system specifically for large target surface detectors and develops a proof-of-concept prototype for verification. The system comprises three components: (1) a curved multi-aperture array, which consists of 61 sub-apertures with an entrance pupil diameter of 5 mm and a focal length of 10 mm; (2) a cooled planar detector; and (3) a relay imaging system, which adopts secondary imaging technology and achieves the matching between the array and detector with only six infrared lenses. The fill factor is introduced to analyze light energy utilization efficiency, providing a theoretical basis for improving the system’s signal-to-noise ratio and spatial information collection capability; meanwhile, the focal length distribution and pupil matching are analyzed to ensure the system’s optical performance. The system operates within the 3.7–4.8 μm wavelength band, with a total focal length of 3.08 mm, F-number of 2, and field of view reaching 108°. Simulations demonstrate that all sub-aperture imaging channels have MTF values greater than 0.47 at 33.3 lp/mm, with distortion less than 3%. Imaging test results verify that the system possesses excellent imaging performance.

PhotonicsVol. 12(11)
Chinese Academy of Sciences (CN), Shanghai Institute of Technical Physics (CN), University of Chinese Academy of Sciences (CN)
Openalex Percentile: Top 69%
Advanced optical system design
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.