Integration of Active Personal Dosimeters, Videos from In-Room Monitors, and Videos from the Surgeon’s Main Panel Reveal Pitfalls in Radiation Protection

We examined whether synchronizing and analyzing three data sources, active personal dosimeter (APD) information, in-room monitoring camera footage, and the operator’s main angiography panel video, could identify opportunities to reduce occupational radiation exposure during cerebral angiography without therapeutic intervention. We analyzed the behavior of eight physicians and radiation doses measured outside the lead apron during 12 diagnostic cerebral angiography procedures performed between January and April 2024. Appropriate use of a ceiling-suspended radiation protective shield (CSRPS) was associated with approximately 70% exposure reduction. In addition, exposure during femoral arteriography (catheter advancement from femoral artery puncture to the aortic arch) accounted for approximately 50% of the total exposure, identifying both as effective intervention points. This approach identified operators’ incorrect use of radiation protection equipment and enabled clear feedback to operators on areas for improvements in radiation protection practices.

Authors

Institutions

Publication Details

Journal
Applied Sciences
Published
2025-10-29
DOI
https://doi.org/10.3390/app152111584
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Integration of Active Personal Dosimeters, Videos from In-Room Monitors, and Videos from the Surgeon’s Main Panel Reveal Pitfalls in Radiation Protection

Go Hitomi, Satoru Matsuzaki, Takashi Moritake, Koichi Nakagami et al.
Applied Sciences
Radiation Dose and Imaging
article

Integration of Active Personal Dosimeters, Videos from In-Room Monitors, and Videos from the Surgeon’s Main Panel Reveal Pitfalls in Radiation Protection

Go Hitomi, Satoru Matsuzaki, Takashi Moritake, Koichi Nakagami, Koichi Morota, Yuko Tanaka, Toru Kurokawa, T Kuriyama, Toru Ishidao
article en

Abstract

We examined whether synchronizing and analyzing three data sources, active personal dosimeter (APD) information, in-room monitoring camera footage, and the operator’s main angiography panel video, could identify opportunities to reduce occupational radiation exposure during cerebral angiography without therapeutic intervention. We analyzed the behavior of eight physicians and radiation doses measured outside the lead apron during 12 diagnostic cerebral angiography procedures performed between January and April 2024. Appropriate use of a ceiling-suspended radiation protective shield (CSRPS) was associated with approximately 70% exposure reduction. In addition, exposure during femoral arteriography (catheter advancement from femoral artery puncture to the aortic arch) accounted for approximately 50% of the total exposure, identifying both as effective intervention points. This approach identified operators’ incorrect use of radiation protection equipment and enabled clear feedback to operators on areas for improvements in radiation protection practices.

Applied SciencesVol. 15(21)
University of Occupational and Environmental Health Japan (JP), National Institute of Public Health (JP), National Institutes for Quantum Science and Technology (JP), Kawasaki Medical School Hospital (JP)
Openalex Percentile: Top 54%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.