Comparative Study on Chiral Separation of Afoxolaner on Polysaccharide‐Based Chiral Stationary Phases by Supercritical Fluid Chromatography and High‐Performance Liquid Chromatography

Supercritical fluid chromatography (SFC)-based chiral separation has been considered as one of the green, highly efficient, and precise methods for the resolution of new chiral pharmaceuticals. Herein, a comparative study of chiral separation of afoxolaner on polysaccharide-based chiral stationary phases (CSPs) by SFC and high-performance liquid chromatography (HPLC) has been conducted. First, effects of chromatographic conditions on chiral separation of afoxolaner by SFC, including CSPs, modifier types and ratios, flow rate, column temperature, and back pressure, have been discussed in detail. Cellulose tris(4-methylbenzoate)-coated CSP demonstrated the best separation performance for afoxolaner by SFC with the resolution of 2.37 among five CSPs. Afoxolaner enantiomers were eluted at 3.53 min and 4.54 min under the optimized SFC conditions, respectively, and the total analysis time was less than 6 min, much shorter than that by HPLC. Subsequently, molecular docking studies revealed that hydrogen bonds and halogen bonds formed by afoxolaner and CSPs dominated the selective interaction for the separation of afoxolaner. Additionally, hydrophobic effects and π-π stacks between afoxolaner and chiral selectors enhanced the resolution of afoxolaner. Moreover, quantitative determination results of afoxolaner by SFC showed good linearity relationships (R<sup>2</sup> > 0.999) between concentration of enantiomers and the corresponding chromatographic peak area in the range from 0.025 to 0.800 mg/mL, and the limit of quantification of enantiomers was 0.025 mg/mL. In brief, SFC separation would offer a green alternative to overcome potential technical bottlenecks in the resolution of new chiral pharmaceuticals.

Authors

Institutions

Publication Details

Journal
Journal of Separation Science
Published
2025-10-01
DOI
https://doi.org/10.1002/jssc.70310
Citations
1
Primary Topic
Analytical Chemistry and Chromatography
Type
article
Field-Weighted Citation Impact
0.76

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Comparative Study on Chiral Separation of Afoxolaner on Polysaccharide‐Based Chiral Stationary Phases by Supercritical Fluid Chromatography and High‐Performance Liquid Chromatography

Chengqiang Xia, Guangzhi Xu, Jiao‐Min Lin, Wei‐Guang Zhang et al.
1 citations
Journal of Separation Science
Analytical Chemistry and Chromatography
0.76
article

Comparative Study on Chiral Separation of Afoxolaner on Polysaccharide‐Based Chiral Stationary Phases by Supercritical Fluid Chromatography and High‐Performance Liquid Chromatography

Chengqiang Xia, Guangzhi Xu, Jiao‐Min Lin, Wei‐Guang Zhang, Jun Fan, Yuxin Fan, Rong Zhu
article en
1 citations

Abstract

Supercritical fluid chromatography (SFC)-based chiral separation has been considered as one of the green, highly efficient, and precise methods for the resolution of new chiral pharmaceuticals. Herein, a comparative study of chiral separation of afoxolaner on polysaccharide-based chiral stationary phases (CSPs) by SFC and high-performance liquid chromatography (HPLC) has been conducted. First, effects of chromatographic conditions on chiral separation of afoxolaner by SFC, including CSPs, modifier types and ratios, flow rate, column temperature, and back pressure, have been discussed in detail. Cellulose tris(4-methylbenzoate)-coated CSP demonstrated the best separation performance for afoxolaner by SFC with the resolution of 2.37 among five CSPs. Afoxolaner enantiomers were eluted at 3.53 min and 4.54 min under the optimized SFC conditions, respectively, and the total analysis time was less than 6 min, much shorter than that by HPLC. Subsequently, molecular docking studies revealed that hydrogen bonds and halogen bonds formed by afoxolaner and CSPs dominated the selective interaction for the separation of afoxolaner. Additionally, hydrophobic effects and π-π stacks between afoxolaner and chiral selectors enhanced the resolution of afoxolaner. Moreover, quantitative determination results of afoxolaner by SFC showed good linearity relationships (R<sup>2</sup> > 0.999) between concentration of enantiomers and the corresponding chromatographic peak area in the range from 0.025 to 0.800 mg/mL, and the limit of quantification of enantiomers was 0.025 mg/mL. In brief, SFC separation would offer a green alternative to overcome potential technical bottlenecks in the resolution of new chiral pharmaceuticals.

Journal of Separation ScienceVol. 48(10)
South China Normal University (CN), Biochemical Society (GB)
National Natural Science Foundation of China, Guangdong Pharmaceutical University
Openalex Percentile: Top 24%
Analytical Chemistry and Chromatography
0.76
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.