Smartphone-based nanozyme immunosensor for rapid quantification of rabies neutralizing antibody

• Smartphone-based immunosensor device (SPIS) was designed and fabricated. • Custom-designed app was in-stored in smartphone for reading immunoassay signals. • Nanozyme engaged competitive immunoassay (CIV) was developed on SPIS platform. • SPIS-CIV was used for rapid quantification of rabies neutralizing antibody. The level of rabies virus neutralizing antibody (RVNA) is a critical indicator to evaluate the protective immunity of vaccinees against rabies virus (RABV) infection. The fluorescent antibody virus neutralization test (FAVN) and the rapid fluorescent focus inhibition test (RFFIT) are the WHO recommended assays for determining the RVNA level after vaccination, but both methods are complicated and time-consuming for 1-5 days. Here we developed a smartphone-based immunosensor platform (SPIS), intelligently integrated with the nanozyme (Au@PtNPs) engaged competitive immunoassay (CIA) in the heavy ion microporous membrane (HIM) filtration microplate and PMMA optical fiber signal transmission (SPIS-CIV) for quantitatively surrogate virus neutralization testing (sVNT) of the surrogate RVNA (sRVNA) in blood samples during 50 min. The highest intra-assay and inter-assay coefficient variations (CV) of SPIS-CIA varied < 13% or 14%, respectively. The linear range of quantification was between 0.4 IU/mL and 10 IU/mL RVNA. The nearly full agreement was found between SPIS-CIA and FAVN for measuring sRVNA or RVNA titers in serum/plasma samples from 27 rabies vaccinees and 64 non-rabies vaccinees (R 2 =0.9941, P< 0.0001), especially SPIS-CIV was accurate for quantification of sRVNA at the border line of protection level (0.5 IU/mL). The limit of detection or quantification (LOD/LOQ) was determined to be 0.25 IU/mL and 0.4 IU/mL, respectively. In conclusion, SPIS-CIA is a rapid, quantitative and precise point-of-care testing for serum sRVNA level, which can be used to predict the protection efficacy against RABV infection in human rabies vaccinees in clinical diagnosis.

Authors

Institutions

Publication Details

Journal
Results in Engineering
Published
2025-10-29
DOI
https://doi.org/10.1016/j.rineng.2025.107965
Primary Topic
Rabies epidemiology and control
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Smartphone-based nanozyme immunosensor for rapid quantification of rabies neutralizing antibody

Chengyao Li, Changchun Tu, Yuyan Wang, Tingting Li et al.
Results in Engineering
Rabies epidemiology and control
article

Smartphone-based nanozyme immunosensor for rapid quantification of rabies neutralizing antibody

Chengyao Li, Changchun Tu, Yuyan Wang, Tingting Li, Cong Wang, Yingying Mao, Enhui Zhang, Jinhui Lu, Yongshui Fu, Ling Zhang, Honghao Wang, Hongwei Li, Jiaxu Wu, Meng Wu
article en

Abstract

• Smartphone-based immunosensor device (SPIS) was designed and fabricated. • Custom-designed app was in-stored in smartphone for reading immunoassay signals. • Nanozyme engaged competitive immunoassay (CIV) was developed on SPIS platform. • SPIS-CIV was used for rapid quantification of rabies neutralizing antibody. The level of rabies virus neutralizing antibody (RVNA) is a critical indicator to evaluate the protective immunity of vaccinees against rabies virus (RABV) infection. The fluorescent antibody virus neutralization test (FAVN) and the rapid fluorescent focus inhibition test (RFFIT) are the WHO recommended assays for determining the RVNA level after vaccination, but both methods are complicated and time-consuming for 1-5 days. Here we developed a smartphone-based immunosensor platform (SPIS), intelligently integrated with the nanozyme (Au@PtNPs) engaged competitive immunoassay (CIA) in the heavy ion microporous membrane (HIM) filtration microplate and PMMA optical fiber signal transmission (SPIS-CIV) for quantitatively surrogate virus neutralization testing (sVNT) of the surrogate RVNA (sRVNA) in blood samples during 50 min. The highest intra-assay and inter-assay coefficient variations (CV) of SPIS-CIA varied < 13% or 14%, respectively. The linear range of quantification was between 0.4 IU/mL and 10 IU/mL RVNA. The nearly full agreement was found between SPIS-CIA and FAVN for measuring sRVNA or RVNA titers in serum/plasma samples from 27 rabies vaccinees and 64 non-rabies vaccinees (R 2 =0.9941, P< 0.0001), especially SPIS-CIV was accurate for quantification of sRVNA at the border line of protection level (0.5 IU/mL). The limit of detection or quantification (LOD/LOQ) was determined to be 0.25 IU/mL and 0.4 IU/mL, respectively. In conclusion, SPIS-CIA is a rapid, quantitative and precise point-of-care testing for serum sRVNA level, which can be used to predict the protection efficacy against RABV infection in human rabies vaccinees in clinical diagnosis.

Results in EngineeringVol. 28
Guangzhou Institutes of Biomedicine and Health (CN), Guangzhou Blood Center (CN), Nanfang Hospital (CN), Guangzhou First People's Hospital (CN), Chongqing Academy of Animal Science (CN), Institute of Special Animal and Plant Sciences (CN), Southern Medical University (CN), Guangzhou Medical University (CN)
Openalex Percentile: Top 67%
Rabies epidemiology and control
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.