A Single-step Platinum Nanoparticle-Enhanced Lateral Flow Immunoassay Platform for Rapid Detection of Influenza A Virus

Lateral flow immunoassays (LFIAs) are widely used point-of-care (POC) diagnostic tools, but their limited sensitivity can hinder reliable diagnoses. To address this limitation, we developed a novel POC diagnostic platform for the highly sensitive detection of influenza A virus (IAV). This developed platform integrates platinum nanoparticle-catalyzed 3,3',5,5'-tetramethylbenzidine (TMB) oxidation for reagent-free, single-step signal amplification with smartphone-based image acquisition and quantitative analysis. This combination of catalytic enhancement and digital interpretation enables rapid, objective, and quantitative diagnostic evaluation, offering improved performance over conventional LFIAs. Upon sample application, the sample flows to complete the immunoreaction at the test line, followed by a chromatographically delayed acidic migration that rehydrates the TMB and delivers it to the captured platinum nanoparticles for signal amplification. This reagent-free, timed enhancement results in approximately 100-fold visual signal amplification compared to unenhanced detection, without the need for additional reagents. Additionally, a custom-developed smartphone application automates image acquisition and quantifies intensity ratios to provide the final diagnosis. The platform achieves a limit of detection of 11.6 pg/mL IAV nucleoprotein within 15 min, offering a 1000-fold increase in sensitivity over traditional LFIAs. In clinical trials, it demonstrated excellent performance, with 96.8% sensitivity and 98.4% specificity compared to RT-PCR. The platform also exhibited semiquantitative capability, with a strong inverse correlation (<i>R</i><sup>2</sup> = 0.832) between RT-PCR Ct values and intensity ratios. This integrated system provides a rapid, low-cost, and user-friendly solution for accurate viral diagnostics.

Authors

Institutions

Publication Details

Journal
ACS Infectious Diseases
Published
2025-10-29
DOI
https://doi.org/10.1021/acsinfecdis.5c00731
Citations
1
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Single-step Platinum Nanoparticle-Enhanced Lateral Flow Immunoassay Platform for Rapid Detection of Influenza A Virus

Myung‐Geun Shin, Min‐Gon Kim, Chang Woon Choi, Donggu Hong et al.
1 citations
ACS Infectious Diseases
Biosensors and Analytical Detection
0.67
article

A Single-step Platinum Nanoparticle-Enhanced Lateral Flow Immunoassay Platform for Rapid Detection of Influenza A Virus

Myung‐Geun Shin, Min‐Gon Kim, Chang Woon Choi, Donggu Hong, K.S. Lee, Hyungbin Park, Young Eun Lee
article en
1 citations

Abstract

Lateral flow immunoassays (LFIAs) are widely used point-of-care (POC) diagnostic tools, but their limited sensitivity can hinder reliable diagnoses. To address this limitation, we developed a novel POC diagnostic platform for the highly sensitive detection of influenza A virus (IAV). This developed platform integrates platinum nanoparticle-catalyzed 3,3',5,5'-tetramethylbenzidine (TMB) oxidation for reagent-free, single-step signal amplification with smartphone-based image acquisition and quantitative analysis. This combination of catalytic enhancement and digital interpretation enables rapid, objective, and quantitative diagnostic evaluation, offering improved performance over conventional LFIAs. Upon sample application, the sample flows to complete the immunoreaction at the test line, followed by a chromatographically delayed acidic migration that rehydrates the TMB and delivers it to the captured platinum nanoparticles for signal amplification. This reagent-free, timed enhancement results in approximately 100-fold visual signal amplification compared to unenhanced detection, without the need for additional reagents. Additionally, a custom-developed smartphone application automates image acquisition and quantifies intensity ratios to provide the final diagnosis. The platform achieves a limit of detection of 11.6 pg/mL IAV nucleoprotein within 15 min, offering a 1000-fold increase in sensitivity over traditional LFIAs. In clinical trials, it demonstrated excellent performance, with 96.8% sensitivity and 98.4% specificity compared to RT-PCR. The platform also exhibited semiquantitative capability, with a strong inverse correlation (<i>R</i><sup>2</sup> = 0.832) between RT-PCR Ct values and intensity ratios. This integrated system provides a rapid, low-cost, and user-friendly solution for accurate viral diagnostics.

ACS Infectious DiseasesVol. 11(11)
Gwangju Institute of Science and Technology (KR), Chonnam National University Hwasun Hospital (KR)
Openalex Percentile: Top 25%
Biosensors and Analytical Detection
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.