Digital slit lamp derived parameters in shallow anterior chamber screening

To evaluate anterior chamber depth (ACD) using diffraction parameters derived from slit-lamp anterior segment (AS) images and assess their diagnostic efficacy in identifying optimal cutoff values for shallow ACD screening. In this cross-sectional study, from September 21, 2022 to June 30, 2023, 75 volunteers (150 eyes). Slit-lamp images (450 images, 3 pictures per eye) were taken, and the ACD was determined using an IOL Master 700. After manual annotation of the anatomical landmarks, the anterior chamber cross-sectional area (ACCSA) and anterior chamber angle (ACA) of the slit-lamp images were measured. Pixel was applied after image processing and feature extraction to predict the ACD. These values were then compared with the ACD acquired from the IOLMaster 700. The correlation between the parameters of the two techniques was determined by Pearson correlation analysis. The anterior chamber area (ACA) under the receiver operating characteristic curve (AUC) was calculated to evaluate the diagnostic efficacy of relevant indicators on images of the ACD. A total of 450 photographs(207 shallow AC and 243 deep AC images) were analyzed. The nasal/temporal anterior chamber cross-sectional area (N/TACCSA), the sum of the cross-sectional areas of the central and nasal/temporal anterior chambers (SACCSA), and nasal/temporal anterior chamber angle (N/TACA) achieved better performance (AUC = 0.819, 95% confidence interval (CI) = 0.752-0.887; AUC = 0.818, 95% CI = 0.748-0.887 and AUC = 0.833, 95% CI = 0.766-0.899, respectively). The image parameter values were strongly positively correlated with the ACD of IOLMaster 700 (central anterior chamber cross-sectional area (CACCSA, N/TACCSA, SACSA, and N/TACA, R = 0.603, 0.651, 0.645, and 0.665, P < 0.01, respectively). Some image parameters not only had a strong positive correlation with the measured ACD values from the IOLMaster 700 but also had the ability to screen for shallow ACD. This study suggested the possibility of estimating the central ACD using AS images.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-29
DOI
https://doi.org/10.1038/s41598-025-21781-1
Primary Topic
Nasal Surgery and Airway Studies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital slit lamp derived parameters in shallow anterior chamber screening

Xingru He, Yiting Gong, Huixin Che, Guangzheng Dai et al.
Scientific Reports
Nasal Surgery and Airway Studies
article

Digital slit lamp derived parameters in shallow anterior chamber screening

Xingru He, Yiting Gong, Huixin Che, Guangzheng Dai, Shiyou Chen, Guanghao Qin, Xin Zhang, Jiahui Zhao, Chenguang Zhang, Yibing Zhou, Shenming Hu
article en

Abstract

To evaluate anterior chamber depth (ACD) using diffraction parameters derived from slit-lamp anterior segment (AS) images and assess their diagnostic efficacy in identifying optimal cutoff values for shallow ACD screening. In this cross-sectional study, from September 21, 2022 to June 30, 2023, 75 volunteers (150 eyes). Slit-lamp images (450 images, 3 pictures per eye) were taken, and the ACD was determined using an IOL Master 700. After manual annotation of the anatomical landmarks, the anterior chamber cross-sectional area (ACCSA) and anterior chamber angle (ACA) of the slit-lamp images were measured. Pixel was applied after image processing and feature extraction to predict the ACD. These values were then compared with the ACD acquired from the IOLMaster 700. The correlation between the parameters of the two techniques was determined by Pearson correlation analysis. The anterior chamber area (ACA) under the receiver operating characteristic curve (AUC) was calculated to evaluate the diagnostic efficacy of relevant indicators on images of the ACD. A total of 450 photographs(207 shallow AC and 243 deep AC images) were analyzed. The nasal/temporal anterior chamber cross-sectional area (N/TACCSA), the sum of the cross-sectional areas of the central and nasal/temporal anterior chambers (SACCSA), and nasal/temporal anterior chamber angle (N/TACA) achieved better performance (AUC = 0.819, 95% confidence interval (CI) = 0.752-0.887; AUC = 0.818, 95% CI = 0.748-0.887 and AUC = 0.833, 95% CI = 0.766-0.899, respectively). The image parameter values were strongly positively correlated with the ACD of IOLMaster 700 (central anterior chamber cross-sectional area (CACCSA, N/TACCSA, SACSA, and N/TACA, R = 0.603, 0.651, 0.645, and 0.665, P < 0.01, respectively). Some image parameters not only had a strong positive correlation with the measured ACD values from the IOLMaster 700 but also had the ability to screen for shallow ACD. This study suggested the possibility of estimating the central ACD using AS images.

Scientific ReportsVol. 15(1)
Jinzhou Central Hospital (CN), He Eye Hospital (CN)
Shenyang Science and Technology Bureau
Openalex Percentile: Top 51%
Nasal Surgery and Airway Studies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.