In-hospital identification of cardiac tamponade after pacemaker implantation: a case report

Introduction: Cardiac tamponade is a rare but life-threatening complication of permanent pacemaker implantation, most commonly caused by lead perforation 1 .Early recognition of the clinical triad and immediate response are crucial for survival.Case report: 74-year-old female was admitted following syncope.Medical history included arterial hypertension, moderate aortic stenosis, heart failure with preserved ejection fraction and coronary artery disease with prior percutaneous coronary intervention of the left anterior descending artery.Telemetry revealed a 6-second asystolic pause, and a dual-chamber permanent pacemaker (Biotronik Enitra 6 DR) was implanted.Several hours later on the ward, nursing staff observed sudden hypotension (BP 70/50 mmHg), atrial fibrillation (130/min) and signs of hemodynamic compromise.Bedside echocardiography confirmed a pericardial effusion up to 2.9 cm with right heart collapse, consistent with tamponade.Immediate fluid resuscitation and urgent triage ensured stabilization and rapid transport to the invasive laboratory.Pericardiocentesis via subxiphoid approach drained 220 ml of hemopericardium with prompt hemodynamic recovery (BP 120/80 mmHg, paced rhythm 60/min).The remainder of hospitalization was uneventful, and the patient was discharged in stable condition with recommendations for rehabilitation and regular device follow-up. Conclusion:Cardiac tamponade after pacemaker implantation is an uncommon but critical complication.In this case, rapid recognition of deterioration by nursing staff on the ward, initiation of volume resuscitation and activation of the transport pathway enabled timely pericardiocentesis.Rapid triage of symptoms and coordinated nurse-led action on the ward remain vital for patient safety. LiterAtUre

Authors

Publication Details

Journal
Cardiologia Croatica
Published
2025-10-29
DOI
https://doi.org/10.15836/ccar2025.281
Primary Topic
Pericarditis and Cardiac Tamponade
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

In-hospital identification of cardiac tamponade after pacemaker implantation: a case report

Ivica Benko, Zrinka Paić, Julija Buljan, Josipa Pekez et al.
Cardiologia Croatica
Pericarditis and Cardiac Tamponade
article

In-hospital identification of cardiac tamponade after pacemaker implantation: a case report

Ivica Benko, Zrinka Paić, Julija Buljan, Josipa Pekez, Anita Pleško
article en

Abstract

Introduction: Cardiac tamponade is a rare but life-threatening complication of permanent pacemaker implantation, most commonly caused by lead perforation 1 .Early recognition of the clinical triad and immediate response are crucial for survival.Case report: 74-year-old female was admitted following syncope.Medical history included arterial hypertension, moderate aortic stenosis, heart failure with preserved ejection fraction and coronary artery disease with prior percutaneous coronary intervention of the left anterior descending artery.Telemetry revealed a 6-second asystolic pause, and a dual-chamber permanent pacemaker (Biotronik Enitra 6 DR) was implanted.Several hours later on the ward, nursing staff observed sudden hypotension (BP 70/50 mmHg), atrial fibrillation (130/min) and signs of hemodynamic compromise.Bedside echocardiography confirmed a pericardial effusion up to 2.9 cm with right heart collapse, consistent with tamponade.Immediate fluid resuscitation and urgent triage ensured stabilization and rapid transport to the invasive laboratory.Pericardiocentesis via subxiphoid approach drained 220 ml of hemopericardium with prompt hemodynamic recovery (BP 120/80 mmHg, paced rhythm 60/min).The remainder of hospitalization was uneventful, and the patient was discharged in stable condition with recommendations for rehabilitation and regular device follow-up. Conclusion:Cardiac tamponade after pacemaker implantation is an uncommon but critical complication.In this case, rapid recognition of deterioration by nursing staff on the ward, initiation of volume resuscitation and activation of the transport pathway enabled timely pericardiocentesis.Rapid triage of symptoms and coordinated nurse-led action on the ward remain vital for patient safety. LiterAtUre

Cardiologia CroaticaVol. 20(11-12)
Openalex Percentile: Top 53%
Pericarditis and Cardiac Tamponade
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

In-hospital identification of cardiac tamponade after pacemaker implantation: a case report — Ivica Benko, Zrinka Paić, et al. · Cardiologia Croatica (2025) | TGRS Research Map | TGRS