A highly accurate and selective non-enzymatic glucose sensor based on a Fe <sub>2</sub> O <sub>3</sub> /CuFe <sub>2</sub> O <sub>4</sub> /graphene nanoplatelet nanocomposite

In this study, a sensitive and accurate non-enzymatic glucose sensor based on a Fe<sub>2</sub>O<sub>3</sub>/CuFe<sub>2</sub>O<sub>4</sub>/graphene nanoplatelet (GNPs) nanocomposite was performed. The nanocomposite was synthesized <i>via</i> a facile hydrothermal method and characterized using FTIR, XRD, SEM, Raman, XPS, cyclic voltammetry (CV) and electrochemical impedance spectroscopy techniques. The integration of Fe<sub>2</sub>O<sub>3</sub> and CuFe<sub>2</sub>O<sub>4</sub> with graphene nanoplatelets (GNPs) provides a synergistic effect, enhanced surface area, high electrochemical conductivity and improved catalytic activity toward glucose oxidation. Electrochemical measurements using CV and chronoamperometry demonstrated excellent sensing performance, with high sensitivity of 62.4 μA mM<sup>-1</sup> cm<sup>-2</sup>, a lower of detection limit of 0.049 μM (S/N = 3) and a widely linear detection range from 5-75 μM and 75-13 000 μM. The sensor exhibited outstanding selectivity against common interfering species (<i>e.g.</i>, dopamine, uric acid and ascorbic acid), along with good stability and reproducibility. These findings suggest that the Fe<sub>2</sub>O<sub>3</sub>/CuFe<sub>2</sub>O<sub>4</sub>/GNPs nanocomposite is a promising applicant for glucose non-enzymatic sensing in clinical and biomedical applications.

Authors

Institutions

Publication Details

Journal
RSC Advances
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ra07666h
Citations
4
Primary Topic
Electrochemical sensors and biosensors
Type
article
Field-Weighted Citation Impact
2.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A highly accurate and selective non-enzymatic glucose sensor based on a Fe 2 O 3 /CuFe 2 O 4 /graphene nanoplatelet nanocomposite

Emna Zouaoui, Messaoud Benounis, Hend S. Magar, A. Boumaza et al.
4 citations
RSC Advances
Electrochemical sensors and biosensors
2.92
article

A highly accurate and selective non-enzymatic glucose sensor based on a Fe 2 O 3 /CuFe 2 O 4 /graphene nanoplatelet nanocomposite

Emna Zouaoui, Messaoud Benounis, Hend S. Magar, A. Boumaza, Lilia Bourouba
article en
4 citations

Abstract

In this study, a sensitive and accurate non-enzymatic glucose sensor based on a Fe<sub>2</sub>O<sub>3</sub>/CuFe<sub>2</sub>O<sub>4</sub>/graphene nanoplatelet (GNPs) nanocomposite was performed. The nanocomposite was synthesized <i>via</i> a facile hydrothermal method and characterized using FTIR, XRD, SEM, Raman, XPS, cyclic voltammetry (CV) and electrochemical impedance spectroscopy techniques. The integration of Fe<sub>2</sub>O<sub>3</sub> and CuFe<sub>2</sub>O<sub>4</sub> with graphene nanoplatelets (GNPs) provides a synergistic effect, enhanced surface area, high electrochemical conductivity and improved catalytic activity toward glucose oxidation. Electrochemical measurements using CV and chronoamperometry demonstrated excellent sensing performance, with high sensitivity of 62.4 μA mM<sup>-1</sup> cm<sup>-2</sup>, a lower of detection limit of 0.049 μM (S/N = 3) and a widely linear detection range from 5-75 μM and 75-13 000 μM. The sensor exhibited outstanding selectivity against common interfering species (<i>e.g.</i>, dopamine, uric acid and ascorbic acid), along with good stability and reproducibility. These findings suggest that the Fe<sub>2</sub>O<sub>3</sub>/CuFe<sub>2</sub>O<sub>4</sub>/GNPs nanocomposite is a promising applicant for glucose non-enzymatic sensing in clinical and biomedical applications.

RSC AdvancesVol. 15(49)
University of Carthage (TN), Abbès Laghrour University of Khenchela (DZ), National Research Centre (EG), University of Skikda (DZ)
Openalex Percentile: Top 8%
Electrochemical sensors and biosensors
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

A highly accurate and selective non-enzymatic glucose sensor based on a Fe <sub>2</sub> O <sub>3</sub> /CuFe <sub>2</sub> O <sub>4</sub> /graphene nanoplatelet nanocomposite — Emna Zouaoui, Messaoud Benounis, et al. · RSC Advances (2025) | TGRS Research Map | TGRS