Evaluation of the Insertion Depth of the iStent Inject W and Its Association with Surgical Outcomes Using Automated Gonioscopy

<b>Background/Objectives</b>: The iStent is a trabecular micro-bypass device used in glaucoma management. Its depth has been evaluated using anterior segment optical coherence tomography; however, no reports have assessed it using gonioscopy. We evaluated the depth of the iStent inject W using the GS-1 automated gonioscope (GS-1) and determined its association with outcomes. <b>Methods:</b> Patients who underwent iStent inject W implantation were followed for 1 year. Angle photographs were obtained using a GS-1. The depth was graded from the GS-1 images as Grades 1 (anterior edge of the flange protruding into the anterior chamber) and 2 (anterior edge embedded within the trabecular meshwork). Based on the two implants' depths, the eyes were categorized into Grades 1 + 1, 2 + 2, and 1 + 2. The percentages of intraocular pressure (IOP) reduction at 12 months were compared among the groups using the Kruskal-Wallis test. <b>Results</b>: Data from 31 patients (41 eyes and 82 stents) were analyzed. The depth distribution for Grades 1 and 2 was 51 (62.2%) and 31 (37.8%) stents, respectively. In the Grade 1 + 1, 2 + 2, and 1 + 2 groups, the number of eyes was 18, 8, and 15, respectively. IOP reductions at 12 months were 12.81 ± 20.27%, 22.85 ± 15.30%, and 16.04 ± 20.41% for the Grade 1 + 1, 2 + 2, and 1 + 2 groups, respectively, with no significant differences (<i>p</i> = 0.493). <b>Conclusions:</b> The impact of insertion depth on outcomes appears to be minimal in eyes where the iStent inject W was visualized using the GS-1. Further studies with larger cohorts should clarify the effects of insertion depth and its interplay with position.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-10-24
DOI
https://doi.org/10.3390/jcm14217547
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluation of the Insertion Depth of the iStent Inject W and Its Association with Surgical Outcomes Using Automated Gonioscopy

AKIMITSU MIWA, Sho Yokoyama, Kei Ichikawa, Kana Yamashita et al.
Journal of Clinical Medicine
Glaucoma and retinal disorders
article

Evaluation of the Insertion Depth of the iStent Inject W and Its Association with Surgical Outcomes Using Automated Gonioscopy

AKIMITSU MIWA, Sho Yokoyama, Kei Ichikawa, Kana Yamashita, Kazuo Ichikawa, Y Takagi, Yukihiro Sakai, Ryo Asano
article en

Abstract

<b>Background/Objectives</b>: The iStent is a trabecular micro-bypass device used in glaucoma management. Its depth has been evaluated using anterior segment optical coherence tomography; however, no reports have assessed it using gonioscopy. We evaluated the depth of the iStent inject W using the GS-1 automated gonioscope (GS-1) and determined its association with outcomes. <b>Methods:</b> Patients who underwent iStent inject W implantation were followed for 1 year. Angle photographs were obtained using a GS-1. The depth was graded from the GS-1 images as Grades 1 (anterior edge of the flange protruding into the anterior chamber) and 2 (anterior edge embedded within the trabecular meshwork). Based on the two implants' depths, the eyes were categorized into Grades 1 + 1, 2 + 2, and 1 + 2. The percentages of intraocular pressure (IOP) reduction at 12 months were compared among the groups using the Kruskal-Wallis test. <b>Results</b>: Data from 31 patients (41 eyes and 82 stents) were analyzed. The depth distribution for Grades 1 and 2 was 51 (62.2%) and 31 (37.8%) stents, respectively. In the Grade 1 + 1, 2 + 2, and 1 + 2 groups, the number of eyes was 18, 8, and 15, respectively. IOP reductions at 12 months were 12.81 ± 20.27%, 22.85 ± 15.30%, and 16.04 ± 20.41% for the Grade 1 + 1, 2 + 2, and 1 + 2 groups, respectively, with no significant differences (<i>p</i> = 0.493). <b>Conclusions:</b> The impact of insertion depth on outcomes appears to be minimal in eyes where the iStent inject W was visualized using the GS-1. Further studies with larger cohorts should clarify the effects of insertion depth and its interplay with position.

Journal of Clinical MedicineVol. 14(21)
Kani Tono Hospital (JP), Japan Community Healthcare Organization (JP), Minamiaoyama Eye Clinic (JP), Chukyo Hospital (JP)
Openalex Percentile: Top 55%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.