Modified glutine adhesives for structural bonding of glued-in rods in timber engineering

The development of sustainable adhesives is becoming an increasingly important topic in timber engineering, as the industry seeks to replace petroleum-based products with bio-based alternatives. Among the natural candidates, glutine adhesives are attractive due to their renewable origin and long history of use, but their application in structural contexts remains limited by poor resistance to moisture and elevated temperatures. This study addresses these weaknesses by investigating straightforward modifications to raw glutine aimed at enhancing its hygrothermal stability. Several strategies were tested, including reducing water content, incorporating fillers such as chalk or sawdust, and adding phenolic cross-linkers (tannic acid, gallic acid, or combinations). Mechanical performance was evaluated at three scales: lap-shear specimens, small-scale glued-in rods, and large-scale glued-in rods. At room temperature, shear strengths of modified glutine adhesives reached values comparable to epoxy references. Under moderate hygrothermal conditions (45 °C/50%–65% RH), formulations such as M31 (chalk + gallic acid) and M35 (chalk + tannic acid) achieved average shear strengths above 6 MPa, showing substantial improvements over the raw reference adhesive. Severe exposure (60 °C/85% RH), however, led to marked reductions in strength, with failure modes shifting from wood tear-out to adhesive failure. The results show that relatively simple modifications can significantly enhance the hygrothermal stability of glutine adhesives and suggest a promising pathway toward sustainable structural bonding. While further studies are required to clarify degradation mechanisms, assess long-term durability, and evaluate scalability, this work demonstrates the potential of modified glutine adhesives as bio-based alternatives in structural timber applications.

Authors

Institutions

Publication Details

Journal
International Journal of Adhesion and Adhesives
Published
2025-10-29
DOI
https://doi.org/10.1016/j.ijadhadh.2025.104164
Citations
1
Primary Topic
Lignin and Wood Chemistry
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Modified glutine adhesives for structural bonding of glued-in rods in timber engineering

Jona Haupt, Lewin Schröder, Thorben Steinberg, Jana Kolbe et al.
1 citations
International Journal of Adhesion and Adhesives
Lignin and Wood Chemistry
0.67
article

Modified glutine adhesives for structural bonding of glued-in rods in timber engineering

Jona Haupt, Lewin Schröder, Thorben Steinberg, Jana Kolbe, Cordula Grunwald, Till Vallée, Stephanie Koesling
article en
1 citations

Abstract

The development of sustainable adhesives is becoming an increasingly important topic in timber engineering, as the industry seeks to replace petroleum-based products with bio-based alternatives. Among the natural candidates, glutine adhesives are attractive due to their renewable origin and long history of use, but their application in structural contexts remains limited by poor resistance to moisture and elevated temperatures. This study addresses these weaknesses by investigating straightforward modifications to raw glutine aimed at enhancing its hygrothermal stability. Several strategies were tested, including reducing water content, incorporating fillers such as chalk or sawdust, and adding phenolic cross-linkers (tannic acid, gallic acid, or combinations). Mechanical performance was evaluated at three scales: lap-shear specimens, small-scale glued-in rods, and large-scale glued-in rods. At room temperature, shear strengths of modified glutine adhesives reached values comparable to epoxy references. Under moderate hygrothermal conditions (45 °C/50%–65% RH), formulations such as M31 (chalk + gallic acid) and M35 (chalk + tannic acid) achieved average shear strengths above 6 MPa, showing substantial improvements over the raw reference adhesive. Severe exposure (60 °C/85% RH), however, led to marked reductions in strength, with failure modes shifting from wood tear-out to adhesive failure. The results show that relatively simple modifications can significantly enhance the hygrothermal stability of glutine adhesives and suggest a promising pathway toward sustainable structural bonding. While further studies are required to clarify degradation mechanisms, assess long-term durability, and evaluate scalability, this work demonstrates the potential of modified glutine adhesives as bio-based alternatives in structural timber applications.

International Journal of Adhesion and AdhesivesVol. 144
Fraunhofer Institute for Manufacturing Technology and Advanced Materials (DE)
Openalex Percentile: Top 25%
Lignin and Wood Chemistry
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.