Rapid quantification and validation of etomidate and dexmedetomidine blood concentrations in rats using a novel portable mass spectrometer

In clinical anesthesia, precise dosing depends on feedback from blood drug concentrations. However, rapid tools for measuring these concentrations are currently limited. This study evaluated the capability of a novel portable mass spectrometer (CELL) to rapidly quantify etomidate and dexmedetomidine in rat plasma. The 50% effective dose (ED<sub>50</sub>) of both drugs was determined using the up-and-down method. CELL's methodology was validated according to standard guidelines. Linear regression and intraclass correlation coefficient (ICC) analyses were conducted to assess the consistency between CELL and HPLC-MS measurements. The ED<sub>50</sub> of etomidate was found to be 0.9 mg/kg and that of dexmedetomidine was 21.1 μg/kg in rats. For etomidate, CELL demonstrated linearity in the range of 210-2,000 ng/ml (<i>y</i> = 427.0<i>x</i> - 30,526, <i>R</i> <sup>2</sup> = 0.995) with a limit of quantitation (LOQ) of 210 ng/ml. For dexmedetomidine, linearity was observed in the range of 6-1,000 ng/ml (<i>y</i> = 14,669<i>x</i> + 109,875, <i>R</i> <sup>2</sup> = 0.997) with an LOQ of 6 ng/ml. In the mixed group, etomidate showed linearity in the range of 100-2,000 ng/ml (<i>y</i> = 431.4<i>x</i> + 11,864, <i>R</i> <sup>2</sup> = 0.996) with an LOQ of 100 ng/ml, while dexmedetomidine exhibited linearity in the range of 5-1,000 ng/ml (<i>y</i> = 14,141<i>x</i> + 52,430, <i>R</i> <sup>2</sup> = 0.997) with an LOQ of 5 ng/ml. A strong linear correlation was observed between CELL and HPLC-MS. These results indicate that CELL provides excellent performance in the rapid and simultaneous quantification of both drugs, supporting real-time monitoring to meet diverse clinical requirements. This approach has strong potential for point-of-care (POC) monitoring in perioperative veterinary and human anesthesia.

Authors

Institutions

Publication Details

Journal
Frontiers in Veterinary Science
Published
2025-10-29
DOI
https://doi.org/10.3389/fvets.2025.1696093
Primary Topic
Anesthesia and Sedative Agents
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Rapid quantification and validation of etomidate and dexmedetomidine blood concentrations in rats using a novel portable mass spectrometer

Sicheng Liu, Deying Gong, Yanhua Huang, Wensheng Zhang et al.
Frontiers in Veterinary Science
Anesthesia and Sedative Agents
article

Rapid quantification and validation of etomidate and dexmedetomidine blood concentrations in rats using a novel portable mass spectrometer

Sicheng Liu, Deying Gong, Yanhua Huang, Wensheng Zhang, Xiaoxiao Li
article en

Abstract

In clinical anesthesia, precise dosing depends on feedback from blood drug concentrations. However, rapid tools for measuring these concentrations are currently limited. This study evaluated the capability of a novel portable mass spectrometer (CELL) to rapidly quantify etomidate and dexmedetomidine in rat plasma. The 50% effective dose (ED<sub>50</sub>) of both drugs was determined using the up-and-down method. CELL's methodology was validated according to standard guidelines. Linear regression and intraclass correlation coefficient (ICC) analyses were conducted to assess the consistency between CELL and HPLC-MS measurements. The ED<sub>50</sub> of etomidate was found to be 0.9 mg/kg and that of dexmedetomidine was 21.1 μg/kg in rats. For etomidate, CELL demonstrated linearity in the range of 210-2,000 ng/ml (<i>y</i> = 427.0<i>x</i> - 30,526, <i>R</i> <sup>2</sup> = 0.995) with a limit of quantitation (LOQ) of 210 ng/ml. For dexmedetomidine, linearity was observed in the range of 6-1,000 ng/ml (<i>y</i> = 14,669<i>x</i> + 109,875, <i>R</i> <sup>2</sup> = 0.997) with an LOQ of 6 ng/ml. In the mixed group, etomidate showed linearity in the range of 100-2,000 ng/ml (<i>y</i> = 431.4<i>x</i> + 11,864, <i>R</i> <sup>2</sup> = 0.996) with an LOQ of 100 ng/ml, while dexmedetomidine exhibited linearity in the range of 5-1,000 ng/ml (<i>y</i> = 14,141<i>x</i> + 52,430, <i>R</i> <sup>2</sup> = 0.997) with an LOQ of 5 ng/ml. A strong linear correlation was observed between CELL and HPLC-MS. These results indicate that CELL provides excellent performance in the rapid and simultaneous quantification of both drugs, supporting real-time monitoring to meet diverse clinical requirements. This approach has strong potential for point-of-care (POC) monitoring in perioperative veterinary and human anesthesia.

Frontiers in Veterinary ScienceVol. 12
Sichuan University (CN), West China Hospital of Sichuan University (CN)
China Postdoctoral Science Foundation, Natural Science Foundation of Sichuan Province, Young Scientists Fund
Openalex Percentile: Top 51%
Anesthesia and Sedative Agents
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.