A Feasibility Study on Noninvasive Blood Glucose Estimation Using Machine Learning Analysis of Near-Infrared Spectroscopy Data

This study explored the feasibility of noninvasive blood glucose (BG) estimation using near-infrared (NIR) spectroscopy with dog blood samples. A sensor module employing three representative wavelengths (770 nm, 850 nm, and 970 nm) was tested on an artificial blood vessel (ABV) and a thin pig skin (TPS) model. BG concentrations were adjusted through dilution and enrichment with injection-grade water and glucose solution, and reference values were obtained from three commercial invasive glucometers. Correlations between NIR spectral responses and glucose variations were quantitatively evaluated using linear, multiple, partial least squares (PLS), logistic regression, regularized linear models, and multilayer perceptron (MLP) analysis. The results revealed distinct negative correlations at 850 nm and 970 nm, identifying these wavelengths as promising candidates for noninvasive glucose sensing. Furthermore, an NIR-glucose database generated from actual dog blood was established, which may serve as a valuable resource for the development of future noninvasive glucose monitoring systems.

Authors

Institutions

Publication Details

Journal
Biosensors
Published
2025-10-25
DOI
https://doi.org/10.3390/bios15110711
Primary Topic
Spectroscopy Techniques in Biomedical and Chemical Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Feasibility Study on Noninvasive Blood Glucose Estimation Using Machine Learning Analysis of Near-Infrared Spectroscopy Data

Byoung Ik Kim, Tae-Wuk Bae, Kee-Koo Kwon, Kwang‐Yong Kim
Biosensors
Spectroscopy Techniques in Biomedical and Chemical Research
article

A Feasibility Study on Noninvasive Blood Glucose Estimation Using Machine Learning Analysis of Near-Infrared Spectroscopy Data

Byoung Ik Kim, Tae-Wuk Bae, Kee-Koo Kwon, Kwang‐Yong Kim
article en

Abstract

This study explored the feasibility of noninvasive blood glucose (BG) estimation using near-infrared (NIR) spectroscopy with dog blood samples. A sensor module employing three representative wavelengths (770 nm, 850 nm, and 970 nm) was tested on an artificial blood vessel (ABV) and a thin pig skin (TPS) model. BG concentrations were adjusted through dilution and enrichment with injection-grade water and glucose solution, and reference values were obtained from three commercial invasive glucometers. Correlations between NIR spectral responses and glucose variations were quantitatively evaluated using linear, multiple, partial least squares (PLS), logistic regression, regularized linear models, and multilayer perceptron (MLP) analysis. The results revealed distinct negative correlations at 850 nm and 970 nm, identifying these wavelengths as promising candidates for noninvasive glucose sensing. Furthermore, an NIR-glucose database generated from actual dog blood was established, which may serve as a valuable resource for the development of future noninvasive glucose monitoring systems.

BiosensorsVol. 15(11)
Electronics and Telecommunications Research Institute (KR), Samjin Pharm (South Korea) (KR)
Openalex Percentile: Top 78%
Spectroscopy Techniques in Biomedical and Chemical Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.