Digital impression accuracy for bone-level and tissue-level implants using scan bodies of different heights

Intraoral scanning has gained acceptance for its accuracy comparable to conventional implant impressions. This study compared digital impression accuracy based on implant placement level and scan body height. Two mandibular partial edentulous models missing the left second premolar and first molar, were used: one with a tissue level implant and the other with a bone level implant. Models were divided into four groups: Group TS-S (bone level, short scan bodies), Group TS-R (bone level, Regular scan bodies), Group SS-S (tissue level, short scan bodies), and Group SS-R (tissue level, Regular scan bodies). Each group was scanned with a model scanner for reference STL files and two intraoral scanners (IOSs; Medit i700, Cerec Primescan) for experimental STL files. Deviation between experimental and reference STL files was measured. The Medit i700 demonstrated smaller scan discrepancies compared to the CEREC Primescan. For both intraoral scanners, the use of short scan bodies resulted in higher trueness than regular scan bodies. Tissue level implants exhibited greater trueness and precision than bone level implants (p < 0.05). These findings indicate that both the implant placement level and scan body height are factors that can influence the accuracy of digital impressions.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-10-27
DOI
https://doi.org/10.1038/s41598-025-20524-6
Citations
1
Primary Topic
Dental Implant Techniques and Outcomes
Type
article
Field-Weighted Citation Impact
1.79

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Digital impression accuracy for bone-level and tissue-level implants using scan bodies of different heights

Jin Haeng Jo, J.W. Lee, Su‐Young Lee
1 citations
Scientific Reports
Dental Implant Techniques and Outcomes
1.79
article

Digital impression accuracy for bone-level and tissue-level implants using scan bodies of different heights

Jin Haeng Jo, J.W. Lee, Su‐Young Lee
article en
1 citations

Abstract

Intraoral scanning has gained acceptance for its accuracy comparable to conventional implant impressions. This study compared digital impression accuracy based on implant placement level and scan body height. Two mandibular partial edentulous models missing the left second premolar and first molar, were used: one with a tissue level implant and the other with a bone level implant. Models were divided into four groups: Group TS-S (bone level, short scan bodies), Group TS-R (bone level, Regular scan bodies), Group SS-S (tissue level, short scan bodies), and Group SS-R (tissue level, Regular scan bodies). Each group was scanned with a model scanner for reference STL files and two intraoral scanners (IOSs; Medit i700, Cerec Primescan) for experimental STL files. Deviation between experimental and reference STL files was measured. The Medit i700 demonstrated smaller scan discrepancies compared to the CEREC Primescan. For both intraoral scanners, the use of short scan bodies resulted in higher trueness than regular scan bodies. Tissue level implants exhibited greater trueness and precision than bone level implants (p < 0.05). These findings indicate that both the implant placement level and scan body height are factors that can influence the accuracy of digital impressions.

Scientific ReportsVol. 15(1)
Seoul National University (KR), St. Mary's Hospital (US), St Mary's Hospital (GB), The Catholic University of Korea Seoul St. Mary's Hospital (KR), Catholic University of Korea (KR)
Korea Health Industry Development Institute
Openalex Percentile: Top 12%
Dental Implant Techniques and Outcomes
1.79
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Digital impression accuracy for bone-level and tissue-level implants using scan bodies of different heights — Jin Haeng Jo, J.W. Lee, et al. · Scientific Reports (2025) | TGRS Research Map | TGRS